ACI 440.6M

Specification for Carbon and Glass Fiber-Reinforced Polymer Bar Materials for Concrete Reinforcement

Organization:
ACI - American Concrete Institute
Year: 2008

Abstract: This specification describes permitted constituent materials, limits on constituent volumes, and minimum performance requirements for carbon and glass fiber-reinforced polymer (FRP) bars to be used as reinforcement for nonprestressed concrete.
Only carbon and glass FRP bars are covered by this specification.
FRP bars made of more than one fiber type (hybrid FRP) are not covered by this specification.
Pultruded FRP bars with no external surface enhancement (that is, plain or smooth bars) to facilitate bond with concrete are not covered by this specification. Similarly, hollow FRP bars are not considered due to lack of documented performance as reinforcement for concrete.
Plain FRP bars used as dowels (that is, devices that transfer shear across concrete joints) where the intended function requires slip of the dowel are not covered by this specification.
This specification does not cover premanufactured grids and gratings made with FRP materials. FRP mats resulting from assembly of deformed FRP bars, however, are covered by this document.
This specification does not cover FRP bars when used for external and near-surface-mounted strengthening applications.
The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
URI: http://yse.yabesh.ir/std;jsein=autho4/handle/yse/93663
Collections :
  • ACI - American Concrete Institute
  • Download PDF : (108.6Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ACI 440.6M

Show full item record

contributor authorACI - American Concrete Institute
date accessioned2017-09-04T16:30:21Z
date available2017-09-04T16:30:21Z
date copyright07/01/2008
date issued2008
identifier otherULOLGCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein=autho4/handle/yse/93663
description abstractThis specification describes permitted constituent materials, limits on constituent volumes, and minimum performance requirements for carbon and glass fiber-reinforced polymer (FRP) bars to be used as reinforcement for nonprestressed concrete.
Only carbon and glass FRP bars are covered by this specification.
FRP bars made of more than one fiber type (hybrid FRP) are not covered by this specification.
Pultruded FRP bars with no external surface enhancement (that is, plain or smooth bars) to facilitate bond with concrete are not covered by this specification. Similarly, hollow FRP bars are not considered due to lack of documented performance as reinforcement for concrete.
Plain FRP bars used as dowels (that is, devices that transfer shear across concrete joints) where the intended function requires slip of the dowel are not covered by this specification.
This specification does not cover premanufactured grids and gratings made with FRP materials. FRP mats resulting from assembly of deformed FRP bars, however, are covered by this document.
This specification does not cover FRP bars when used for external and near-surface-mounted strengthening applications.
The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
languageEnglish
titleACI 440.6Mnum
titleSpecification for Carbon and Glass Fiber-Reinforced Polymer Bar Materials for Concrete Reinforcementen
typestandard
page10
statusActive
treeACI - American Concrete Institute:;2008
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian