IPC TM-650 2.4.8.3A
Peel Strength of Metallic Clad Laminate at Elevated Temperature (Hot Air Method)
Organization:
IPC - Association Connecting Electronics Industries
Year: 1994
Abstract: This test is designed to determine the peel strength of the metal cladding to the base laminate while exposed to elevated temperature by means of heated air chamber; and to evaluate the base laminate material after the peel strength test is completed for degradation due to the conditioning.
Collections
:
-
Statistics
IPC TM-650 2.4.8.3A
Show full item record
contributor author | IPC - Association Connecting Electronics Industries | |
date accessioned | 2017-09-04T16:52:32Z | |
date available | 2017-09-04T16:52:32Z | |
date copyright | 34669 | |
date issued | 1994 | |
identifier other | WTNOCAAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;jsery=autho162s7D83081DAC426159DD6EFDEC014A/handle/yse/116106 | |
description abstract | This test is designed to determine the peel strength of the metal cladding to the base laminate while exposed to elevated temperature by means of heated air chamber; and to evaluate the base laminate material after the peel strength test is completed for degradation due to the conditioning. | |
language | English | |
title | IPC TM-650 2.4.8.3A | num |
title | Peel Strength of Metallic Clad Laminate at Elevated Temperature (Hot Air Method) | en |
type | standard | |
page | 3 | |
status | Active | |
tree | IPC - Association Connecting Electronics Industries:;1994 | |
contenttype | fulltext |