Standard Test Methods for Short-Term Indentation and Residual Indentation of Resilient Floor Covering

ASTM F1914-18

Organization:
ASTM - ASTM International
Year: 2023

Abstract: 11.1 The indentation and the residual indentation of resilient floor covering is important since the resistance and recovery from indentation reflects on the ability of the resilient floor covering to perform properly after installation. 11.2 The indentation of a resilient floor covering shall be measured using a specified type of indentor, flat or spherical, under a specified load and time. 11.3 The residual indentation of a resilient floor covering shall be measured after a specified recovery time. 11.4 See Table 1 for detailed testing and conditioning requirements by products (specification) type.
URI: http://yse.yabesh.ir/std;jsessionid=190419C4AB017808E65B78A0B48BF7AE/handle/yse/337598
Collections :
  • ASTM - ASTM International
  • Download PDF : (673.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Test Methods for Short-Term Indentation and Residual Indentation of Resilient Floor Covering

Show full item record

contributor authorASTM - ASTM International
date accessioned2024-12-17T22:30:44Z
date available2024-12-17T22:30:44Z
date copyright2023
date issued2023
identifier otherf1914-18r23.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=190419C4AB017808E65B78A0B48BF7AE/handle/yse/337598
description abstract11.1 The indentation and the residual indentation of resilient floor covering is important since the resistance and recovery from indentation reflects on the ability of the resilient floor covering to perform properly after installation. 11.2 The indentation of a resilient floor covering shall be measured using a specified type of indentor, flat or spherical, under a specified load and time. 11.3 The residual indentation of a resilient floor covering shall be measured after a specified recovery time. 11.4 See Table 1 for detailed testing and conditioning requirements by products (specification) type.
languageEnglish
titleStandard Test Methods for Short-Term Indentation and Residual Indentation of Resilient Floor Coveringen
titleASTM F1914-18num
typestandard
page5
statusActive
treeASTM - ASTM International:;2023
contenttypefulltext
scope1.1 This test method covers procedures to determine short-term indentation and residual indentation of resilient flooring, when subjected to concentrated loads. 1.2 The test methods appear in the following order:     Section Indentation by McBurney2 Test  4 to 10 Indentation and Residual Indentation  11 to 15 1.3 There are two procedures with their respective apparatus. The first (McBurney Test) is described in Sections 4 to 10 and is restricted to a spherical foot. It is only used for initial indentation measurements of VCT. The second is described in Sections 11 to 15 and has interchangeable feet with variable geometry. It is used to measure initial and residual indentation. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/F1914-18R23