Ventilation and Acceptable Indoor Air Quality in Residential Buildings

ASHRAE 62.2 ADD X

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2020

Abstract: Several questions have arisen from users of the standard and within the SSPC regarding requirements for installation and operation of mechanical ventilation systems. The changes in this addendum are intended to clarify the requirements for complying with the standard. The changes introduce a specific paragraph to address operation requirements (Section 4.4.2). Note that the deletion of the last sentence in Section 4.4.1 does not remove the requirement to label controls. These are still required per existing text in Section 6.2 “Controls and Labeling”. Note: In this addendum, changes to the current standard are indicated in the text by under-lining (for additions) and (for deletions) unless the instructions specifically mention some other means of indicating the changes
URI: http://yse.yabesh.ir/std;jsessionid=2340FFB03E809BEAD71C07B80262C7B1/handle/yse/280679
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (496.5Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Ventilation and Acceptable Indoor Air Quality in Residential Buildings

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2020-08-03T11:59:58Z
date available2020-08-03T11:59:58Z
date issued2020
identifier otherILTPMGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=2340FFB03E809BEAD71C07B80262C7B1/handle/yse/280679
description abstractSeveral questions have arisen from users of the standard and within the SSPC regarding requirements for installation and operation of mechanical ventilation systems. The changes in this addendum are intended to clarify the requirements for complying with the standard. The changes introduce a specific paragraph to address operation requirements (Section 4.4.2). Note that the deletion of the last sentence in Section 4.4.1 does not remove the requirement to label controls. These are still required per existing text in Section 6.2 “Controls and Labeling”. Note: In this addendum, changes to the current standard are indicated in the text by under-lining (for additions) and (for deletions) unless the instructions specifically mention some other means of indicating the changes
languageEnglish
titleVentilation and Acceptable Indoor Air Quality in Residential Buildingsen
titleASHRAE 62.2 ADD Xnum
typestandard
page5
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2020
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian