Now showing items 1-20 of 35

      • SMACNA 1072 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2007
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: The purpose of this manual is to guide building managers and contractors on controlling construction contaminants so they do not impact building occupants.
        Poor indoor air quality (IAQ) is more likely to impact the ...
      • SMACNA 1079 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1994
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: FOREWORD
        The Sheet Metal and Air Conditioning Contractors' National Association presents this Ducted Electric Heat Guide for Air Handling Systems to assist contractors, designers and authorities ...
      • SMACNA 1108 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2008
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: INTRODUCTION
        This guide is a compilation of standards and construction techniques which have received wide acceptance for the fabrication and installation of ducts designed to convey air and gases, ...
      • SMACNA 1127 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2011
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: FOREWORD
        This first edition of Guyed Steel Stacks – Welded Longseam and Spiral Lockseam Construction – is intended for use by contractors, fabricators, and designers of heating ...
      • SMACNA 1167 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2011
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: INTRODUCTION
        This publication is devoted exclusively to vertical, uniform diameter, freestanding stacks founded at ground elevation. Tables are provided for stacks of specific height ranging from 20 ...
      • SMACNA 1378 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1995
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: PURPOSE
        This manual proposes to accomplish three practical objectives:
        (a) To develop minimum standards for fabrication and installation of plastic duct which can be used as a reference for contract ...
      • SMACNA 1429 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1994
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: The HVAC Systems Commissioning Manual is intended to cover the full range of HVAC equipment and systems typically found in commercial and institutional buildings.
        The level of commissioning varies to suit the ...
      • SMACNA 1494 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2011
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: FOREWORD
        This second edition updating and revision of the Retrofit manual comes at a time when green building guidelines, standards and codes are either recently finished or nearing completion. These ...
      • SMACNA 1520 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1999
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: The scope of this manual includes the determination of the necessary construction details for the fabrication and installation of round metallic industrial duct work within the following general categories, and as further ...
      • SMACNA 1546 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1997
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: This manual covers the physical properties, manufacture, construction, installation and methods of testing fiberglass reinforced thermosetting plastic duct, intended for air conveyance in corrosive environments, as ...
      • SMACNA 1572 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1996
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: INTRODUCTION
        The industrial sheet metal contractor is often required to provide a steel stack as part of the system for process exhaust ventilation.
        This handbook is devoted exclusively to free-standing ...
      • SMACNA 1624 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1997
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: FOREWORD
        As the industry has changed over the last few years, and with changes coming on the horizon, the SMACNA contractor needs to be equipped to meet these challenges. New construction is only one ...
      • SMACNA 1637 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1998
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: FOREWORD
        As the Indoor Air Quality (IAQ) industry has changed over the years, and with coming changes on the horizon, the SMACNA contractor needs to be equipped to handle this every changing market and ...
      • SMACNA 1689 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;1998
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: PURPOSE
        This text is intended to provide a thorough background in the design and installation of residential heating and air conditioning systems. Although detailed design information cannot be provided ...
      • SMACNA 1754 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2001
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: FOREWORD
        As housing construction grows more complex, and the building business becomes more involved, SMACNA recognizes the need for a reference on the proper fabrication and installation of exterior ...
      • SMACNA 1767 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2001
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: The information and drawings in this manual are presented primarily to illustrate the elements of construction and installation of commercial kitchen ventilation systems. The information is intended to encourage more ...
      • SMACNA 1780 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2002
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: FOREWORD
        This handbook has been extensively updated for 2002 from the original 1983 publication and includes all of the many changes that have takes piace in the industry since the 1990's. We have added ...
      • SMACNA 1793 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2012
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: FOREWORD
        This seventh edition of the Architectural Sheet Metal Manual has many changes and several additions. Changes include new chapters and details on penetrations, additional and revised tables in ...
      • SMACNA 1806 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2002
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: This document contains accepted practices for the fabrication and installation of sheet metal lagging. This document serves to establish standard methods to fabricate and install sheet metal lagging systems. This ...
      • SMACNA 1819 

        Type: standard
        Source: SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2002
        Organization : SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
        Abstract: This guide reviews the pertinent language contained in the model codes, the terminology used in the codes and other relevant documents, and the requirements of plans and specifications as: (1) developed by architects, ...