SMACNA 1943

RECTANGULAR INDUSTRIAL DUCT CONSTRUCTION STANDARDS - SECOND EDITION; SI Version

Organization:
SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
Year: 2007

Abstract: The scope of this manual includes the determination of the necessary construction details for the fabrication and installation of rectangular metallic industrial duct within the following general categories, and as further detailed in the scope of individual chapters, through a variety of both analytical and empirical methods:
• Fabricated from flat sheet or plate panels, using welded seam, grooved lockseam, Pittsburgh lock, and standing seam techniques.
• From commercial grades of carbon, galvanized, aluminized, or stainless steel, or aluminum of the various grades and types as described in Chapter 3.
• For a design pressure within the range from negative 35.0 kPa to positive 35.0 kPa.
• To be supported at intervals not exceeding 10.0 m.
• For a design temperature not exceeding the specific operating limits listed for each type and grade of metal included in Chapter 3.
• With panel widths (W) up to 4.0 m.
• Listing of rated stiffeners, flanges, hanger and support elements, and the methods for selecting them for specific structural loads.
• An accepted industry practices for the fabrication and installation of rectangular metallic industrial duct, with its fittings, appurtenances, accessories, insulation, lagging, hangers and supports.
PURPOSE
There were three primary purposes behind the development of this manual:
• To develop minimum standards for the fabrication and installation of metallic rectangular industrial duct systems.
• To develop new, and collect existing, duct construction practices and data to serve as an authoritative source of accepted industrial practices for contractors, design engineers, facility managers, and pollution control authorities.
• To provide an authoritative source of documentation and terminology for operations involved in the construction and installation of rectangular metallic industrial duct.
URI: http://yse.yabesh.ir/std;jsessionid=47037D83FCDCAC426159DD6E273C9FCD/handle/yse/191819
Collections :
  • SMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
  • Download PDF : (4.662Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    SMACNA 1943

Show full item record

contributor authorSMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.
date accessioned2017-09-04T18:08:48Z
date available2017-09-04T18:08:48Z
date copyright08/01/2007
date issued2007
identifier otherGSTJFCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=47037D83FCDCAC426159DD6E273C9FCD/handle/yse/191819
description abstractThe scope of this manual includes the determination of the necessary construction details for the fabrication and installation of rectangular metallic industrial duct within the following general categories, and as further detailed in the scope of individual chapters, through a variety of both analytical and empirical methods:
• Fabricated from flat sheet or plate panels, using welded seam, grooved lockseam, Pittsburgh lock, and standing seam techniques.
• From commercial grades of carbon, galvanized, aluminized, or stainless steel, or aluminum of the various grades and types as described in Chapter 3.
• For a design pressure within the range from negative 35.0 kPa to positive 35.0 kPa.
• To be supported at intervals not exceeding 10.0 m.
• For a design temperature not exceeding the specific operating limits listed for each type and grade of metal included in Chapter 3.
• With panel widths (W) up to 4.0 m.
• Listing of rated stiffeners, flanges, hanger and support elements, and the methods for selecting them for specific structural loads.
• An accepted industry practices for the fabrication and installation of rectangular metallic industrial duct, with its fittings, appurtenances, accessories, insulation, lagging, hangers and supports.
PURPOSE
There were three primary purposes behind the development of this manual:
• To develop minimum standards for the fabrication and installation of metallic rectangular industrial duct systems.
• To develop new, and collect existing, duct construction practices and data to serve as an authoritative source of accepted industrial practices for contractors, design engineers, facility managers, and pollution control authorities.
• To provide an authoritative source of documentation and terminology for operations involved in the construction and installation of rectangular metallic industrial duct.
languageEnglish
titleSMACNA 1943num
titleRECTANGULAR INDUSTRIAL DUCT CONSTRUCTION STANDARDS - SECOND EDITION; SI Versionen
typestandard
statusActive
treeSMACNA - Sheet Metal and Air Conditioning Contractors' National Association Inc.:;2007
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian