MIL-STD-40076

PRESERVATION AND PACKING OF ROCKET AND MISSILE SYSTEMS EQUIPMENT FOR SHIPMENT

Organization:
ARMY - MI - Aviation & Missile Command
Year: 1997

Abstract: This standard establishes the general requirements for preservation, packing, and loading for shipment of rocket and missile systems ground support equipment and hazardous items for worldwide movement and storage. Intended Use: This standard is intended to be used in support of packaging data sheets to the extent specified therein, or when specified in the absence of the packaging data sheets, it will provide basic requirements for preservation, packing, and loading of missile weapon system equipment. The static-free breather dehumidification system was designed to provide a simple means for preserving equipment contained in large rigid containers such as shelters and vans. The expansion and contraction of the air contained in large shelters result in unusual problems in maintaining hermetic seals of air tightness. The free breather system overcomes many of these problems by reducing the degree of air pressure tightness required so that any shelter or container which is or can be sealed against free entry of air is a satisfactory item for use of the system. A free breather system consists of two basic parts, a designed venting system, and a bed of desiccant, through which all air is exchanged. The length to diameter ratio of the flexible tubing used to attach the free breather assembly to the external vent shall never be less than 10 to I, and in this instance, the tubing shall be not less than 30 inches in length. A major factor in the success or failure of the system is the air flow through the desiccant and not around it.
URI: http://yse.yabesh.ir/std;jsessionid=47037D83FCDCAC426159DD6E273C9FCD/handle/yse/68432
Subject: Boxes
Collections :
  • ARMY - MI - Aviation & Missile Command
  • Download PDF : (150.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-STD-40076

Show full item record

contributor authorARMY - MI - Aviation & Missile Command
date accessioned2017-09-04T16:05:10Z
date available2017-09-04T16:05:10Z
date copyright35781
date issued1997
identifier otherRVIBEAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=47037D83FCDCAC426159DD6E273C9FCD/handle/yse/68432
description abstractThis standard establishes the general requirements for preservation, packing, and loading for shipment of rocket and missile systems ground support equipment and hazardous items for worldwide movement and storage. Intended Use: This standard is intended to be used in support of packaging data sheets to the extent specified therein, or when specified in the absence of the packaging data sheets, it will provide basic requirements for preservation, packing, and loading of missile weapon system equipment. The static-free breather dehumidification system was designed to provide a simple means for preserving equipment contained in large rigid containers such as shelters and vans. The expansion and contraction of the air contained in large shelters result in unusual problems in maintaining hermetic seals of air tightness. The free breather system overcomes many of these problems by reducing the degree of air pressure tightness required so that any shelter or container which is or can be sealed against free entry of air is a satisfactory item for use of the system. A free breather system consists of two basic parts, a designed venting system, and a bed of desiccant, through which all air is exchanged. The length to diameter ratio of the flexible tubing used to attach the free breather assembly to the external vent shall never be less than 10 to I, and in this instance, the tubing shall be not less than 30 inches in length. A major factor in the success or failure of the system is the air flow through the desiccant and not around it.
languageEnglish
titleMIL-STD-40076num
titlePRESERVATION AND PACKING OF ROCKET AND MISSILE SYSTEMS EQUIPMENT FOR SHIPMENTen
typestandard
page35
statusActive
treeARMY - MI - Aviation & Missile Command:;1997
contenttypefulltext
subject keywordsBoxes
subject keywordsshipping
subject keywordsBreather
subject keywordsfree
subject keywordsCARC/CPP
subject keywordsContainers
subject keywordsCrates
subject keywordsshipping
subject keywordsPackage
subject keywordsShipping and loading
subject keywordsVent
subject keywordsfree breathing
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian