CSA/AM ANSI Z83.8-2009/CSA 2.6-2009
Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-Fired Duct Furnaces - Fourth Edition; Incorporating Erratum: February 27, 2012
Organization:
CSA/AM - CSA America, Inc.
Year: 2009
Abstract: This standard applies to newly produced gas fired-duct furnaces, packaged heaters and unit heaters with input rates up to and including 10,000,000 Btu/h (2 931 kW) and utility heaters with inputs up to and including 400,000 Btu/hr (117.2 kW) constructed entirely of new, unused parts and materials:
a. For use with natural gas with inlet gas pressures up to and including 5.0 psi (34.5 kPa); unit heaters, packaged heaters and duct furnace with burners having inputs rates over 400,000 Btu/hr (117 228 kW) may have higher inlet pressures.
b. For use with liquefied petroleum gases; and
c. Convertible for use with natural gas and liquefied petroleum gases, when provision is made for the conversion from one gas to the other.
a. For use with natural gas with inlet gas pressures up to and including 5.0 psi (34.5 kPa); unit heaters, packaged heaters and duct furnace with burners having inputs rates over 400,000 Btu/hr (117 228 kW) may have higher inlet pressures.
b. For use with liquefied petroleum gases; and
c. Convertible for use with natural gas and liquefied petroleum gases, when provision is made for the conversion from one gas to the other.
Collections
:
-
Statistics
CSA/AM ANSI Z83.8-2009/CSA 2.6-2009
Show full item record
contributor author | CSA/AM - CSA America, Inc. | |
date accessioned | 2017-09-04T15:04:01Z | |
date available | 2017-09-04T15:04:01Z | |
date copyright | 2009.01.01 | |
date issued | 2009 | |
identifier other | KXYCDFAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;jsessionid=94C855E48DF4B83399F154F279F912DC/handle/yse/1341 | |
description abstract | This standard applies to newly produced gas fired-duct furnaces, packaged heaters and unit heaters with input rates up to and including 10,000,000 Btu/h (2 931 kW) and utility heaters with inputs up to and including 400,000 Btu/hr (117.2 kW) constructed entirely of new, unused parts and materials: a. For use with natural gas with inlet gas pressures up to and including 5.0 psi (34.5 kPa); unit heaters, packaged heaters and duct furnace with burners having inputs rates over 400,000 Btu/hr (117 228 kW) may have higher inlet pressures. b. For use with liquefied petroleum gases; and c. Convertible for use with natural gas and liquefied petroleum gases, when provision is made for the conversion from one gas to the other. | |
language | English | |
title | CSA/AM ANSI Z83.8-2009/CSA 2.6-2009 | num |
title | Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-Fired Duct Furnaces - Fourth Edition; Incorporating Erratum: February 27, 2012 | en |
type | standard | |
page | 220 | |
status | Revised | |
tree | CSA/AM - CSA America, Inc.:;2009 | |
contenttype | fulltext |