• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • CSA/AM - CSA America, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • CSA/AM - CSA America, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

CSA/AM ANSI Z21.58-2007/CSA 1.6-2007

Outdoor Cooking Gas Appliances - Third Edition

Organization:
CSA/AM - CSA America, Inc.
Year: 2007

Abstract: This standard applies to newly produced outdoor cooking gas appliances (see Part IV, Definitions), constructed entirely of new, unused parts and materials. Outdoor cooking gas appliances submitted for examination under this standard shall be classified as either portable, stationary or built-in.
This standard applies to outdoor cooking gas appliances mounted to the exterior of a recreational vehicle (RV Grills see Part IV, Definitions) for connection to the recreational vehicle's low pressure LP gas supply system (see 1.1.7). It does not apply to outdoor cooking gas appliances for installation in the interior living space of a recreational vehicle.
This standard does not apply to outdoor cooking gas appliances for installation in or on boats.
An outdoor cooking gas appliance may be a:
a. Broiler unit;
b. Top or surface unit;
c. Combination of "a" or "b" above, or any other outdoor cooking gas appliance; or
d. RV grill.
Outdoor cooking gas appliances may be:
a. For connection to a fixed fuel piping system.
b. For connection to a remote self-contained liquefied petroleum gas supply system (see Part IV, Definitions), provided the appliance is supplied with remote mounting and retention means for the attachment of a single cylinder with a maximum size in accordance with 1.1.5-b or 1.1.54-c and instructions for installing the mounting and retention means within the built-in enclosure.
c. For connection to a self-contained liquefied petroleum gas supply system with an integral cylinder mounting means, for attachment to a single cylinder:
1. Outdoor cooking gas appliances with input ratings less than 80,000 Btu/h shall be designed to accommodate a vertically mounted cylinder with a maximum size of 20 lb (9.1kg) of fuel.
2. Outdoor cooking gas appliances with input rating greater than or equal to 80,000 Btu/h shall be designed to accommodate a vertically mounted cylinder with a maximum size of 30 lb (13.6 kg) of fuel.
d. For connection to a self-contained liquefied petroleum gas supply system with an integral cylinder mounting means for the attachment of not more than two vertically mounted vapor withdrawl cylinders, each with a maximum size of 20 lb (9.1 kg) of fuel for outdoor cooking gas appliances with input ratings greating than or equal to 80,000 Btu/h.
An outdoor cooking gas appliance conforming to 1.1.4-b2, and that is capable of accepting either a 20 lb (9.1 kg) or a 30 lb (13.6 kg) LP-gas cylinder, shall have all applicable tests in Part I, Construction, and Part II, Performance, conducted with both size cylinders.
This standard applies to outdoor cooking gas appliances operating at inlet gas pressures not to exceed ½ psi (3.5 kPa) for connection to a fixed fuel piping system:
a. For use with natural gas;
b. For use with manufactured gas;
c. For use with mixed gas;
d. For use with liquefied petroleum gases; and
e. For use with LP gas-air mixtures.
This standard also applies to outdoor cooking gas appliances designed for connection to self-contained LP-gas supply systems (see 1.5, Fixed Fuel Piping Systems):
a. Operating at regulated outlet pressures not to exceed 11 iwc (2.74 kPa); and
b. Operating at regulated outlet pressures in excess of 11 iwc (2.74 kPa) but not greater than 5 psi (34.5 kPa).
The construction of outdoor cooking gas appliances for use with the above-mentioned gases is covered under Part I, Construction.
The performance of outdoor cooking gas appliances for use with the above-mentioned gases is covered under Part II, Performance.
Built-in outdoor cooking gas appliances may be:
a. For connection to a fixed fuel piping system; or
b. For connection to a remote self-contained liquefied petroleum gas supply system (see Part IV, Definitions), provided the appliance is supplied with remote mounting and retention means for the attachment of a single cylinder with a maximum size in accordance with 1.1.5-b and instructions for installing the mounting and retention means within the built-in enclosure.
An outdoor cooking gas appliance conforming to 1.1.5-c2, and that is capable of accepting either a 20 lb (9.1 kg) or a 30 lb (13.6 kg) LP-gas cylinder, shall have all applicable tests in Part I, Construction, and Part II, Performance, conducted with both size cylinders.
An outdoor cooking gas appliance having integral mounting and retention means shall be designed so a space 20 lb (9.1 kg) or 30 lb (13.6kg) LP-gas cylinder cannot be stored within any enclosure, or under the firebox of the appliance.
Throughout this document gauge pressures are designated in pounds per square inch, (psi) and kilopascals (kPa). Use of the terminology "psig" is not used. Where "psi" is used it is understood to be pound per square inch gauge. Absolute pressures are not used in this standard.
If a value for a measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. (Also see Exhibit C, Items Unique to Canada.)
Exhibit A contains the LP-Gas Cylinder Label.
Exhibit B contains provisions that are unique to the United States.
Exhibit C contains provisions that are unique to Canada.
Exhibit D contains a list of standards specifically referenced in this standard, and sources from which these reference standards may be obtained.
An outdoor cooking gas appliance covered by this standard need not comply with the provisions of the Standard for Gas-Fired Appliances for Outdoor Installations, CAN1-2.21.
URI: http://yse.yabesh.ir/std;jsessionid=94C855E48DF4B83399F154F279F912DC/handle/yse/53533
Collections :
  • CSA/AM - CSA America, Inc.
  • Download PDF : (3.033Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA/AM ANSI Z21.58-2007/CSA 1.6-2007

Show full item record

contributor authorCSA/AM - CSA America, Inc.
date accessioned2017-09-04T15:50:27Z
date available2017-09-04T15:50:27Z
date copyright2007.03.01
date issued2007
identifier otherQHADACAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=94C855E48DF4B83399F154F279F912DC/handle/yse/53533
description abstractThis standard applies to newly produced outdoor cooking gas appliances (see Part IV, Definitions), constructed entirely of new, unused parts and materials. Outdoor cooking gas appliances submitted for examination under this standard shall be classified as either portable, stationary or built-in.
This standard applies to outdoor cooking gas appliances mounted to the exterior of a recreational vehicle (RV Grills see Part IV, Definitions) for connection to the recreational vehicle's low pressure LP gas supply system (see 1.1.7). It does not apply to outdoor cooking gas appliances for installation in the interior living space of a recreational vehicle.
This standard does not apply to outdoor cooking gas appliances for installation in or on boats.
An outdoor cooking gas appliance may be a:
a. Broiler unit;
b. Top or surface unit;
c. Combination of "a" or "b" above, or any other outdoor cooking gas appliance; or
d. RV grill.
Outdoor cooking gas appliances may be:
a. For connection to a fixed fuel piping system.
b. For connection to a remote self-contained liquefied petroleum gas supply system (see Part IV, Definitions), provided the appliance is supplied with remote mounting and retention means for the attachment of a single cylinder with a maximum size in accordance with 1.1.5-b or 1.1.54-c and instructions for installing the mounting and retention means within the built-in enclosure.
c. For connection to a self-contained liquefied petroleum gas supply system with an integral cylinder mounting means, for attachment to a single cylinder:
1. Outdoor cooking gas appliances with input ratings less than 80,000 Btu/h shall be designed to accommodate a vertically mounted cylinder with a maximum size of 20 lb (9.1kg) of fuel.
2. Outdoor cooking gas appliances with input rating greater than or equal to 80,000 Btu/h shall be designed to accommodate a vertically mounted cylinder with a maximum size of 30 lb (13.6 kg) of fuel.
d. For connection to a self-contained liquefied petroleum gas supply system with an integral cylinder mounting means for the attachment of not more than two vertically mounted vapor withdrawl cylinders, each with a maximum size of 20 lb (9.1 kg) of fuel for outdoor cooking gas appliances with input ratings greating than or equal to 80,000 Btu/h.
An outdoor cooking gas appliance conforming to 1.1.4-b2, and that is capable of accepting either a 20 lb (9.1 kg) or a 30 lb (13.6 kg) LP-gas cylinder, shall have all applicable tests in Part I, Construction, and Part II, Performance, conducted with both size cylinders.
This standard applies to outdoor cooking gas appliances operating at inlet gas pressures not to exceed ½ psi (3.5 kPa) for connection to a fixed fuel piping system:
a. For use with natural gas;
b. For use with manufactured gas;
c. For use with mixed gas;
d. For use with liquefied petroleum gases; and
e. For use with LP gas-air mixtures.
This standard also applies to outdoor cooking gas appliances designed for connection to self-contained LP-gas supply systems (see 1.5, Fixed Fuel Piping Systems):
a. Operating at regulated outlet pressures not to exceed 11 iwc (2.74 kPa); and
b. Operating at regulated outlet pressures in excess of 11 iwc (2.74 kPa) but not greater than 5 psi (34.5 kPa).
The construction of outdoor cooking gas appliances for use with the above-mentioned gases is covered under Part I, Construction.
The performance of outdoor cooking gas appliances for use with the above-mentioned gases is covered under Part II, Performance.
Built-in outdoor cooking gas appliances may be:
a. For connection to a fixed fuel piping system; or
b. For connection to a remote self-contained liquefied petroleum gas supply system (see Part IV, Definitions), provided the appliance is supplied with remote mounting and retention means for the attachment of a single cylinder with a maximum size in accordance with 1.1.5-b and instructions for installing the mounting and retention means within the built-in enclosure.
An outdoor cooking gas appliance conforming to 1.1.5-c2, and that is capable of accepting either a 20 lb (9.1 kg) or a 30 lb (13.6 kg) LP-gas cylinder, shall have all applicable tests in Part I, Construction, and Part II, Performance, conducted with both size cylinders.
An outdoor cooking gas appliance having integral mounting and retention means shall be designed so a space 20 lb (9.1 kg) or 30 lb (13.6kg) LP-gas cylinder cannot be stored within any enclosure, or under the firebox of the appliance.
Throughout this document gauge pressures are designated in pounds per square inch, (psi) and kilopascals (kPa). Use of the terminology "psig" is not used. Where "psi" is used it is understood to be pound per square inch gauge. Absolute pressures are not used in this standard.
If a value for a measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. (Also see Exhibit C, Items Unique to Canada.)
Exhibit A contains the LP-Gas Cylinder Label.
Exhibit B contains provisions that are unique to the United States.
Exhibit C contains provisions that are unique to Canada.
Exhibit D contains a list of standards specifically referenced in this standard, and sources from which these reference standards may be obtained.
An outdoor cooking gas appliance covered by this standard need not comply with the provisions of the Standard for Gas-Fired Appliances for Outdoor Installations, CAN1-2.21.
languageEnglish
titleCSA/AM ANSI Z21.58-2007/CSA 1.6-2007num
titleOutdoor Cooking Gas Appliances - Third Editionen
typestandard
page142
statusActive
treeCSA/AM - CSA America, Inc.:;2007
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian