Show simple item record

Explosive atmospheres - Part 18: Equipment protection by encapsulation "m" - 12.23.01

contributor authorISA - International Society of Automation
date accessioned2017-09-04T17:26:29Z
date available2017-09-04T17:26:29Z
date copyright01/01/2012
date issued2012
identifier otherCKKLAFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=A33FFBB4A04818B251172099FA6814F7/handle/yse/149608
description abstractThis standard gives the specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components with the type of protection encapsulation "m" intended for use in explosive gas atmospheres or explosive dust atmospheres.
This standard applies only for encapsulated electrical equipment, encapsulated parts of electrical equipment and encapsulated Ex components (hereinafter always referred to as "m" equipment) where the rated voltage does not exceed 11 kV.
The application of electrical equipment in atmospheres, which may contain explosive gas as well as combustible dust simultaneously may require additional protective measures.
This standard does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances
This standard does not take account of any risk due to an emission of flammable or toxic gas from the dust.
This standard supplements and modifies the general requirements of ANSI/ISA- 60079-0. Where a requirement of this standard conflicts with a requirement of ANSI/ISA-60079-0, the requirement of this standard shall take precedence.
languageEnglish
titleISA 60079-18num
titleExplosive atmospheres - Part 18: Equipment protection by encapsulation "m" - 12.23.01en
typestandard
page50
statusActive
treeISA - International Society of Automation:;2012
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record