ISA TR12.12.04

Electrical Equipment in a Class I, Division 2/Zone 2 Hazardous Location

Organization:
ISA - International Society of Automation
Year: 2011

Abstract: Introduction
When electrical equipment is used in locations in which fire or explosion hazards may exist due to flammable gases or vapours, flammable liquids, combustible dust, or ignitable fibers or flyings, the National Electrical Code® (NEC®), ANSI/NFPA 70 requires special precautions to be taken in equipment construction and installation to minimize risks of fire and explosions. There are several protection techniques in common use, each of which has its own set of advantages and disadvantages. Other countries, including Canada, utilize varying wiring methods, so the contents of this report may not be applicable to countries other than the United States.
A location in which the fire or explosion hazard exists infrequently and for short periods is designated as a Division 2 or Zone 2 location. Two of the primary protection techniques for Division 2 or Zone 2 locations are "Nonincendive equipment" or "Non-sparking equipment". This Technical Report is intended to explain these protection techniques and to clarify the associated terminology. This Technical Report also addresses field wiring for Division 2/Zone 2 locations.
Division 2 equipment is permitted to be marked and used in Zone 2 hazardous locations per the NEC®, Section 505.9(C)(1).
Zone 2 equipment, in accordance with ANSI/ISA-60079-15, is permitted to be marked and used in Division 2 hazardous location per the NEC®, Section 501.5.
The term "combustible material" will be used throughout this Technical Report to refer to materials mentioned above, i.e., flammable gases, flammable liquid produced vapours, or combustible liquid produced vapours. Similarly, the term "hazardous location" will be used in place of the phrase "hazardous (classified) location" used in the NEC® and in the product standards. Finally, although combustible materials pose a fire hazard, the primary concern is an explosion.
URI: http://yse.yabesh.ir/std;jsessionid=A33FFBB4A04818B251172099FA6814F7/handle/yse/197676
Collections :
  • ISA - International Society of Automation
  • Download PDF : (97.88Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ISA TR12.12.04

Show full item record

contributor authorISA - International Society of Automation
date accessioned2017-09-04T18:14:45Z
date available2017-09-04T18:14:45Z
date copyright06/20/2011
date issued2011
identifier otherHIJNNEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=A33FFBB4A04818B251172099FA6814F7/handle/yse/197676
description abstractIntroduction
When electrical equipment is used in locations in which fire or explosion hazards may exist due to flammable gases or vapours, flammable liquids, combustible dust, or ignitable fibers or flyings, the National Electrical Code® (NEC®), ANSI/NFPA 70 requires special precautions to be taken in equipment construction and installation to minimize risks of fire and explosions. There are several protection techniques in common use, each of which has its own set of advantages and disadvantages. Other countries, including Canada, utilize varying wiring methods, so the contents of this report may not be applicable to countries other than the United States.
A location in which the fire or explosion hazard exists infrequently and for short periods is designated as a Division 2 or Zone 2 location. Two of the primary protection techniques for Division 2 or Zone 2 locations are "Nonincendive equipment" or "Non-sparking equipment". This Technical Report is intended to explain these protection techniques and to clarify the associated terminology. This Technical Report also addresses field wiring for Division 2/Zone 2 locations.
Division 2 equipment is permitted to be marked and used in Zone 2 hazardous locations per the NEC®, Section 505.9(C)(1).
Zone 2 equipment, in accordance with ANSI/ISA-60079-15, is permitted to be marked and used in Division 2 hazardous location per the NEC®, Section 501.5.
The term "combustible material" will be used throughout this Technical Report to refer to materials mentioned above, i.e., flammable gases, flammable liquid produced vapours, or combustible liquid produced vapours. Similarly, the term "hazardous location" will be used in place of the phrase "hazardous (classified) location" used in the NEC® and in the product standards. Finally, although combustible materials pose a fire hazard, the primary concern is an explosion.
languageEnglish
titleISA TR12.12.04num
titleElectrical Equipment in a Class I, Division 2/Zone 2 Hazardous Locationen
typestandard
page22
statusActive
treeISA - International Society of Automation:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian