NFPA 496

English -- Standard for Purged and Pressurized Enclosures for Electrical Equipment - Effective Date: 06/02/2016

Organization:
NFPA - (NFPA) - National Fluid Power Association
Year: 2017

Abstract: Scope: This standard applies to purging and pressurizing for the following: (1) Electrical equipment located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70 (2) Electrical equipment containing sources of flammable vapors or gases and located in either classified or unclassified areas (3) Control rooms or buildings located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70 (4) Analyzer rooms containing sources of flammable vapors or gases and located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70 This standard does not apply to electrical equipment located in: (1) Areas classified as Class I, Zone 0 (2) Areas classified as Class III (3) Areas where flammable liquids may be splashed or spilled on the electrical equipment Purpose. This standard provides information on the methods for purging and pressurizing enclosures to prevent ignition of a flammable atmosphere. Such an atmosphere may be introduced into the enclosure by a surrounding external atmosphere or by an internal source. By these means, electrical equipment that is not otherwise acceptable for a flammable atmosphere may be utilized in accordance with Article 500 or Article 505 of NFPA 70
URI: http://yse.yabesh.ir/std;jsessionid=BDA61AF91C83DA2CC6ADE3C645CDCD14/handle/yse/233755
Collections :
  • NFPA - (NFPA) - National Fluid Power Association
  • Download PDF : (335.5Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NFPA 496

Show full item record

contributor authorNFPA - (NFPA) - National Fluid Power Association
date accessioned2017-10-18T11:01:06Z
date available2017-10-18T11:01:06Z
date copyright2017.01.01
date issued2017
identifier otherMVNFQFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=BDA61AF91C83DA2CC6ADE3C645CDCD14/handle/yse/233755
description abstractScope: This standard applies to purging and pressurizing for the following: (1) Electrical equipment located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70 (2) Electrical equipment containing sources of flammable vapors or gases and located in either classified or unclassified areas (3) Control rooms or buildings located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70 (4) Analyzer rooms containing sources of flammable vapors or gases and located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70 This standard does not apply to electrical equipment located in: (1) Areas classified as Class I, Zone 0 (2) Areas classified as Class III (3) Areas where flammable liquids may be splashed or spilled on the electrical equipment Purpose. This standard provides information on the methods for purging and pressurizing enclosures to prevent ignition of a flammable atmosphere. Such an atmosphere may be introduced into the enclosure by a surrounding external atmosphere or by an internal source. By these means, electrical equipment that is not otherwise acceptable for a flammable atmosphere may be utilized in accordance with Article 500 or Article 505 of NFPA 70
languageEnglish
titleNFPA 496num
titleEnglish -- Standard for Purged and Pressurized Enclosures for Electrical Equipment - Effective Date: 06/02/2016en
typestandard
page29
statusActive
treeNFPA - (NFPA) - National Fluid Power Association:;2017
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian