DOD-I-85390

INDICATOR, TIME-TEMPERATURE, CARD CHEMICALLY ACTIVATED, METRIC

Organization:
NAVY - AS - Naval Air Systems Command
Year: 1980

Abstract: This specification covers a time-temperature controlled, chemically activated, irreversible indicator card for use with time-temperature sensitive, limited shelf life products.
The time-temperature indicator card covered by this specification shall be of the following classes.
                                                  Time-temperature Class          Application                        characteristics    1            Freezer exposure                   210 days at −20°C    2            Long term freezer exposure         One year at −20°C                                                   (50 days at −5°C)                                                   (5 days at 25°C)    3            Ambient exposure                   40 days at 25°C                                                   (20 days at 30°C)                                                   (3 days at 49°C)    4            Long term ambient exposure         70 days at 30°C                                                   (6 days at 49°C)

Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Engineering Specifications and Standards Department (Code 93), Naval Air Engineering Center, Lakehurst, New Jersey 08733, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or letter.
Intended Use: The time-temperature indicators covered by this specification are intended to be packaged with products having a limited shelf-life and which are temperature sensitive. The indicators should not be exposed to direct sunlight. Relative humidity in excess of 50 percent will slightly decrease the reactivity of the indicators. The time-temperature graph for each class of indicator card is utilized in the establishment of the product end point.
URI: http://yse.yabesh.ir/std;jsessionid=CA5893FD081D20689A53733F877BE14C/handle/yse/222048
Collections :
  • NAVY - AS - Naval Air Systems Command
  • Download PDF : (469.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    DOD-I-85390

Show full item record

contributor authorNAVY - AS - Naval Air Systems Command
date accessioned2017-09-04T18:40:28Z
date available2017-09-04T18:40:28Z
date copyright05/21/1980
date issued1980
identifier otherJUQPDAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=CA5893FD081D20689A53733F877BE14C/handle/yse/222048
description abstractThis specification covers a time-temperature controlled, chemically activated, irreversible indicator card for use with time-temperature sensitive, limited shelf life products.
The time-temperature indicator card covered by this specification shall be of the following classes.
                                                  Time-temperature Class          Application                        characteristics    1            Freezer exposure                   210 days at −20°C    2            Long term freezer exposure         One year at −20°C                                                   (50 days at −5°C)                                                   (5 days at 25°C)    3            Ambient exposure                   40 days at 25°C                                                   (20 days at 30°C)                                                   (3 days at 49°C)    4            Long term ambient exposure         70 days at 30°C                                                   (6 days at 49°C)

Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Engineering Specifications and Standards Department (Code 93), Naval Air Engineering Center, Lakehurst, New Jersey 08733, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or letter.
Intended Use: The time-temperature indicators covered by this specification are intended to be packaged with products having a limited shelf-life and which are temperature sensitive. The indicators should not be exposed to direct sunlight. Relative humidity in excess of 50 percent will slightly decrease the reactivity of the indicators. The time-temperature graph for each class of indicator card is utilized in the establishment of the product end point.
languageEnglish
titleDOD-I-85390num
titleINDICATOR, TIME-TEMPERATURE, CARD CHEMICALLY ACTIVATED, METRICen
typestandard
page9
statusActive
treeNAVY - AS - Naval Air Systems Command:;1980
contenttypefulltext