MIL-W-18445D
WINDOWS, NON-ICING, LAMINATED FLAT GLASS, ELECTRICALLY HEATED WITH CONTROLS
Organization:
NAVY - SH - Naval Sea Systems Command (Ship Systems)
Year: 1980
Abstract: This specification covers non-icing, flat laminated, electrically heated glass windows contained in metal frames, with temperature controls necessary for operation. The windows are to provide clear vision aboard ships during cold weather operating conditions.
Controllers shall be of the following types, as specified (see 6.2.1):
Type I - Remote controller actuated by a temperature sensor embedded in the window.
Type II - Surface controller actuated by an integral temperature sensor for controller replacement on windows not having embedded sensors. Intended Use: Non-icing windows are intended for use in pilot houses or similar locations in Naval ships or shore installations where constant clear vision is required under icing and fogging conditions down to minus 20°F with a 40 knot wind and an ice accumulation rate of 6 inches per hour.
Controllers shall be of the following types, as specified (see 6.2.1):
Type I - Remote controller actuated by a temperature sensor embedded in the window.
Type II - Surface controller actuated by an integral temperature sensor for controller replacement on windows not having embedded sensors. Intended Use: Non-icing windows are intended for use in pilot houses or similar locations in Naval ships or shore installations where constant clear vision is required under icing and fogging conditions down to minus 20°F with a 40 knot wind and an ice accumulation rate of 6 inches per hour.
Collections
:
Show full item record
| contributor author | NAVY - SH - Naval Sea Systems Command (Ship Systems) | |
| date accessioned | 2017-09-04T18:16:42Z | |
| date available | 2017-09-04T18:16:42Z | |
| date copyright | 29584 | |
| date issued | 1980 | |
| identifier other | HNNKDAAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;jsessioutho4703177793325273135A68A10958014A0Fa/handle/yse/199632 | |
| description abstract | This specification covers non-icing, flat laminated, electrically heated glass windows contained in metal frames, with temperature controls necessary for operation. The windows are to provide clear vision aboard ships during cold weather operating conditions. Controllers shall be of the following types, as specified (see 6.2.1): Type I - Remote controller actuated by a temperature sensor embedded in the window. Type II - Surface controller actuated by an integral temperature sensor for controller replacement on windows not having embedded sensors. Intended Use: Non-icing windows are intended for use in pilot houses or similar locations in Naval ships or shore installations where constant clear vision is required under icing and fogging conditions down to minus 20°F with a 40 knot wind and an ice accumulation rate of 6 inches per hour. | |
| language | English | |
| title | MIL-W-18445D | num |
| title | WINDOWS, NON-ICING, LAMINATED FLAT GLASS, ELECTRICALLY HEATED WITH CONTROLS | en |
| type | standard | |
| page | 17 | |
| status | Active | |
| tree | NAVY - SH - Naval Sea Systems Command (Ship Systems):;1980 | |
| contenttype | fulltext |

درباره ما