DIN EN 13616-2
English -- Overfill prevention devices for static tanks for liquid fuels - Part 2: Overfill prevention devices without a closure device;
German -- Ueberfuellsicherungen fuer ortsfeste Tanks fuer fluessige Brenn- und Kraftstoffe - Teil 2: Ueberfuellsicherungen ohne Schliesseinrichtung
Organization:
DIN - Deutsches Institut fš?r Normung e. V.
Year: 2016
Abstract: Scope: This European Standard contains requirements, test and assessment methods, marking, labelling and packaging applicable to overfill prevention devices without a closure device. The overfill prevention device without a closure device is usually composed of — overfill prevention sensor consists of — sensor, — electrical interface, — mechanical interface, — overfill prevention controller according to EN 16657. These overfill prevention devices are intended to be used in/with underground or above ground, nonpressurized, static tanks designed for liquid fuels. NOTE 1 Liquid fuel means liquids for internal combustion engines, heating/cooling boilers and generators. NOTE 2 In further text, for liquid fuels the term liquid is used.
Collections
:
Show full item record
| contributor author | DIN - Deutsches Institut fš?r Normung e. V. | |
| date accessioned | 2017-10-18T11:03:01Z | |
| date available | 2017-10-18T11:03:01Z | |
| date copyright | 2016.11.01 | |
| date issued | 2016 | |
| identifier other | PCZOSFAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;jsessioutho4703177793325273135A68A10958014A0Fa/handle/yse/234228 | |
| description abstract | Scope: This European Standard contains requirements, test and assessment methods, marking, labelling and packaging applicable to overfill prevention devices without a closure device. The overfill prevention device without a closure device is usually composed of — overfill prevention sensor consists of — sensor, — electrical interface, — mechanical interface, — overfill prevention controller according to EN 16657. These overfill prevention devices are intended to be used in/with underground or above ground, nonpressurized, static tanks designed for liquid fuels. NOTE 1 Liquid fuel means liquids for internal combustion engines, heating/cooling boilers and generators. NOTE 2 In further text, for liquid fuels the term liquid is used. | |
| language | English | |
| title | DIN EN 13616-2 | num |
| title | English -- Overfill prevention devices for static tanks for liquid fuels - Part 2: Overfill prevention devices without a closure device | en |
| title | German -- Ueberfuellsicherungen fuer ortsfeste Tanks fuer fluessige Brenn- und Kraftstoffe - Teil 2: Ueberfuellsicherungen ohne Schliesseinrichtung | other |
| type | standard | |
| page | 39 | |
| status | Active | |
| tree | DIN - Deutsches Institut fš?r Normung e. V.:;2016 | |
| contenttype | fulltext |

درباره ما