DIN EN 12566-7

English -- Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units;
German -- Kleinklaeranlagen fuer bis zu 50 EW - Teil 7: Vorgefertigte Anlagen fuer eine dritte Reinigungsstufe

Organization:
DIN - Deutsches Institut fš?r Normung e. V.
Year: 2016

Abstract: Scope: This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit (see Figure 1). It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Equivalent secondary treated effluent may come from existing systems. Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP), polydicyclopentadiene (PDCPD) and flexible sheets (HDPE, PP, PVE and EPDM). This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit. This standard does not apply to tertiary treatment systems forming part of units covered by EN 12566-3 and EN 12566-6. This standard does not cover the systems for microorganism reduction.
URI: http://yse.yabesh.ir/std;jsessioutho4703177793325273135A68A10958014A0Fa/handle/yse/234747
Collections :
  • DIN - Deutsches Institut für Normung e. V.
  • Download PDF : (2.454Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    DIN EN 12566-7

Show full item record

contributor authorDIN - Deutsches Institut fš?r Normung e. V.
date accessioned2017-10-18T11:05:09Z
date available2017-10-18T11:05:09Z
date copyright2016.12.01
date issued2016
identifier otherRQOKTFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessioutho4703177793325273135A68A10958014A0Fa/handle/yse/234747
description abstractScope: This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit (see Figure 1). It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Equivalent secondary treated effluent may come from existing systems. Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP), polydicyclopentadiene (PDCPD) and flexible sheets (HDPE, PP, PVE and EPDM). This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit. This standard does not apply to tertiary treatment systems forming part of units covered by EN 12566-3 and EN 12566-6. This standard does not cover the systems for microorganism reduction.
languageEnglish
titleDIN EN 12566-7num
titleEnglish -- Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment unitsen
titleGerman -- Kleinklaeranlagen fuer bis zu 50 EW - Teil 7: Vorgefertigte Anlagen fuer eine dritte Reinigungsstufeother
typestandard
page51
statusActive
treeDIN - Deutsches Institut fš?r Normung e. V.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian