DIN EN ISO 11990-2

English -- Lasers and laser-related equipment - Determination of laser resistance of tracheal tubes - Part 2: Tracheal tube cuffs (ISO 11990-2:2010);
German -- Laser und Laseranlagen - Bestimmung der Laserresistenz von Trachealtuben - Teil 2: Trachealtubusmanschetten (ISO 11990-2:2010)

Organization:
DIN - Deutsches Institut fš?r Normung e. V.
Year: 2016

Abstract: Scope: This part of ISO 11990 specifies a method of testing the continuous wave (cw) resistance of the cuff regions of tracheal tubes designed to resist ignition by a laser. Other components of the system, such as the inflation system and shaft (as defined in ISO 11990-1), are outside the scope of this part of ISO 11990. NOTE 1 The method for testing the laser resistance of the tracheal tube shaft is in the scope of ISO 11990-1. The specified test method can be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions. It does not describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual clinical use conditions. However, the results of this test method may be used as an element of a fire risk assessment which takes into account all of the factors that are pertinent to an assessment of the hazard of a particular end use. NOTE 2 Caution should be observed in interpreting these results, since the direct applicability of the results of this test method to the clinical situation has not been fully established. NOTE 3 This test method might involve hazardous materials, operations and equipment. This part of ISO 11990 provides advice on minimizing some of the risks associated with its use but does not purport to address all such risks. It is the responsibility of the user of this test method to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use
URI: http://yse.yabesh.ir/std;jsessioutho4703177793325273135A68A10958014A0Fa/handle/yse/235244
Collections :
  • DIN - Deutsches Institut für Normung e. V.
  • Download PDF : (2.197Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    DIN EN ISO 11990-2

Show full item record

contributor authorDIN - Deutsches Institut fš?r Normung e. V.
date accessioned2017-10-18T11:07:14Z
date available2017-10-18T11:07:14Z
date copyright2016.02.01
date issued2016
identifier otherUDVKOFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessioutho4703177793325273135A68A10958014A0Fa/handle/yse/235244
description abstractScope: This part of ISO 11990 specifies a method of testing the continuous wave (cw) resistance of the cuff regions of tracheal tubes designed to resist ignition by a laser. Other components of the system, such as the inflation system and shaft (as defined in ISO 11990-1), are outside the scope of this part of ISO 11990. NOTE 1 The method for testing the laser resistance of the tracheal tube shaft is in the scope of ISO 11990-1. The specified test method can be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions. It does not describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual clinical use conditions. However, the results of this test method may be used as an element of a fire risk assessment which takes into account all of the factors that are pertinent to an assessment of the hazard of a particular end use. NOTE 2 Caution should be observed in interpreting these results, since the direct applicability of the results of this test method to the clinical situation has not been fully established. NOTE 3 This test method might involve hazardous materials, operations and equipment. This part of ISO 11990 provides advice on minimizing some of the risks associated with its use but does not purport to address all such risks. It is the responsibility of the user of this test method to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use
languageEnglish
titleDIN EN ISO 11990-2num
titleEnglish -- Lasers and laser-related equipment - Determination of laser resistance of tracheal tubes - Part 2: Tracheal tube cuffs (ISO 11990-2:2010)en
titleGerman -- Laser und Laseranlagen - Bestimmung der Laserresistenz von Trachealtuben - Teil 2: Trachealtubusmanschetten (ISO 11990-2:2010)other
typestandard
page19
statusActive
treeDIN - Deutsches Institut fš?r Normung e. V.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian