NACE TM0113
Evaluating the Accuracy of Field-Grade Reference Electrodes - Item No. 21265
Organization:
NACE - NACE International
Year: 2013
Abstract: General
This standard describes a test method for evaluating the accuracy of copper/copper sulfate and silver/silver chloride reference electrodes used in the field for measurement of structure-to-electrolyte potentials.
This standard does not apply to the evaluation of reference electrodes used in laboratory work.
This standard should be used in conjunction with the practices described in the latest revision of NACE Standard TM01011 and NACE Standard TM0497,2 when appropriate.
This standard describes a test method for evaluating the accuracy of copper/copper sulfate and silver/silver chloride reference electrodes used in the field for measurement of structure-to-electrolyte potentials.
This standard does not apply to the evaluation of reference electrodes used in laboratory work.
This standard should be used in conjunction with the practices described in the latest revision of NACE Standard TM01011 and NACE Standard TM0497,2 when appropriate.
Collections
:
Show full item record
contributor author | NACE - NACE International | |
date accessioned | 2017-09-04T18:00:57Z | |
date available | 2017-09-04T18:00:57Z | |
date copyright | 2013.01.08 | |
date issued | 2013 | |
identifier other | ABCEGFAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;jsessioutho4703AF679D40527369728F1E273C9FCD/handle/yse/183984 | |
description abstract | General This standard describes a test method for evaluating the accuracy of copper/copper sulfate and silver/silver chloride reference electrodes used in the field for measurement of structure-to-electrolyte potentials. This standard does not apply to the evaluation of reference electrodes used in laboratory work. This standard should be used in conjunction with the practices described in the latest revision of NACE Standard TM01011 and NACE Standard TM0497,2 when appropriate. | |
language | English | |
title | NACE TM0113 | num |
title | Evaluating the Accuracy of Field-Grade Reference Electrodes - Item No. 21265 | en |
type | standard | |
page | 12 | |
status | Active | |
tree | NACE - NACE International:;2013 | |
contenttype | fulltext |