ITU-T K.72

(Pre-Published) Protection of telecommunication lines using metallic conductors against lightning – Risk management

Organization:
ITU-T - International Telecommunication Union/ITU Telcommunication Sector
Year: 2011

Abstract: This Recommendation deals with the risk management of lightning protection of telecommunication networks using cables with metallic conductors.
The risk assessment is limited to physical damage and failure of insulation of telecommunication lines (buried or aerial cables, shielded or unshielded cables) which can cause the loss of service.
This Recommendation provides a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure allows the selection of appropriate protection measures to be adopted to reduce the risk to a level at or below the tolerable limit.
This Recommendation shall be used together with [ITU-T K.47], which provides the risk assessment and the protection measures against lightning flashes to the telecommunication line and to structures connected to the telecommunication line, and [ITU-T K.46], which provides the risk assessment and the protection measures against lightning flashes near the telecommunication line.
The protection need for line equipment (such as multiplexers, power amplifiers, optical network units) and line termination equipment is not considered in this Recommendation and it should be evaluated using the risk assessment applied to the structure where the equipment is located (i.e., exchange, customer's building, or remote electronic site).
The protection of persons using telecommunication equipment inside the customer's structure, from dangerous situations caused by touch voltages is outside the scope of this Recommendation and it should be evaluated using the risk assessment applied to the customer's structure.
URI: http://yse.yabesh.ir/std;jsessioutho9193177793325273135A68A1095801/handle/yse/223206
Subject: Lightning
Collections :
  • ITU-T - International Telecommunication Union/ITU Telcommunication Sector
  • Download PDF : (184.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ITU-T K.72

Show full item record

contributor authorITU-T - International Telecommunication Union/ITU Telcommunication Sector
date accessioned2017-09-04T18:41:43Z
date available2017-09-04T18:41:43Z
date copyright2011.06.01
date issued2011
identifier otherALONMEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessioutho9193177793325273135A68A1095801/handle/yse/223206
description abstractThis Recommendation deals with the risk management of lightning protection of telecommunication networks using cables with metallic conductors.
The risk assessment is limited to physical damage and failure of insulation of telecommunication lines (buried or aerial cables, shielded or unshielded cables) which can cause the loss of service.
This Recommendation provides a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure allows the selection of appropriate protection measures to be adopted to reduce the risk to a level at or below the tolerable limit.
This Recommendation shall be used together with [ITU-T K.47], which provides the risk assessment and the protection measures against lightning flashes to the telecommunication line and to structures connected to the telecommunication line, and [ITU-T K.46], which provides the risk assessment and the protection measures against lightning flashes near the telecommunication line.
The protection need for line equipment (such as multiplexers, power amplifiers, optical network units) and line termination equipment is not considered in this Recommendation and it should be evaluated using the risk assessment applied to the structure where the equipment is located (i.e., exchange, customer's building, or remote electronic site).
The protection of persons using telecommunication equipment inside the customer's structure, from dangerous situations caused by touch voltages is outside the scope of this Recommendation and it should be evaluated using the risk assessment applied to the customer's structure.
languageEnglish
titleITU-T K.72num
title(Pre-Published) Protection of telecommunication lines using metallic conductors against lightning – Risk managementen
typestandard
page14
statusActive
treeITU-T - International Telecommunication Union/ITU Telcommunication Sector:;2011
contenttypefulltext
subject keywordsLightning
subject keywordsnode
subject keywordsprotection
subject keywordsrisk
subject keywordsrisk assessment
subject keywordsSPD
subject keywordssurge
subject keywordstelecommunication line.
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian