IEC 60601-2-50

English -- Medical electrical equipment ? Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment - Edition 2.1;
French -- Appareils ‚lectrom‚dicaux ? Partie 2-50: Exigences particuliŠres pour la s‚curit‚ de base et les performances essentielles des appareils de phototh‚rapie pour nouveau-n‚s - Edition 2.1

Organization:
IEC - International Electrotechnical Commission
Year: 2016

Abstract: Scope: Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT PHOTOTHERAPY EQUIPMENT, as defined in 201.3.203 of this standard, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard specifies safety requirements for INFANT PHOTOTHERAPY EQUIPMENT, but alternate methods of compliance with a specific clause by demonstrating equivalent safety will not be judged as non-compliant if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This particular standard does not apply to: – devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use, for information see IEC 80601-2-35; – INFANT INCUBATORS; for information see IEC 60601-2-19; – INFANT TRANSPORT INCUBATORS; for information, see IEC 60601-2-20; – INFANT RADIANT WARMERS; for information see IEC 60601-2-21.  
URI: http://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/235266
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (1.490Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEC 60601-2-50

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2017-10-18T11:07:19Z
date available2017-10-18T11:07:19Z
date copyright2016.04.01
date issued2016
identifier otherUGJZOFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/235266
description abstractScope: Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT PHOTOTHERAPY EQUIPMENT, as defined in 201.3.203 of this standard, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard specifies safety requirements for INFANT PHOTOTHERAPY EQUIPMENT, but alternate methods of compliance with a specific clause by demonstrating equivalent safety will not be judged as non-compliant if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This particular standard does not apply to: – devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use, for information see IEC 80601-2-35; – INFANT INCUBATORS; for information see IEC 60601-2-19; – INFANT TRANSPORT INCUBATORS; for information, see IEC 60601-2-20; – INFANT RADIANT WARMERS; for information see IEC 60601-2-21.  
languageEnglish, French
titleIEC 60601-2-50num
titleEnglish -- Medical electrical equipment ? Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment - Edition 2.1en
titleFrench -- Appareils ‚lectrom‚dicaux ? Partie 2-50: Exigences particuliŠres pour la s‚curit‚ de base et les performances essentielles des appareils de phototh‚rapie pour nouveau-n‚s - Edition 2.1other
typestandard
page126
statusActive
treeIEC - International Electrotechnical Commission:;2016
contenttypefulltext