IEC 80601-2-35

English -- Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads or mattresses and intended for heating in medical use - Edition 2.1; Consolidated Reprint;
French -- Appareils ‚lectrom‚dicaux ? Partie 2-35: Exigences particuliŠres pour la s‚curit‚ de base et les performances essentielles des dispositifs de r‚chauffage utilisant des couvertures, des coussins ou des matelas chauffants et destin‚s au r‚chauffage des patients en usage m‚dical - Edition 2.1; Consolidated Reprint

Organization:
IEC - International Electrotechnical Commission
Year: 2016

Abstract: Scope: Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HEATING DEVICES using BLANKETS, PADS or MATTRESSES in medical use, also referred to as ME EQUIPMENT. HEATING DEVICES intended to prewarm a bed are included in the scope of this International Standard. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. If a clause or subclause is specifically intended to apply to a specifically defined type of ME EQUIPMENT, as is the case with FORCED AIR DEVICES, then the clause or subclause is entitled as such. Clauses or subclauses that apply to all types of ME EQUIPMENT within the scope of this standard are not specifically entitled. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard does not apply to: – HEATING DEVICES intended for physiotherapy; – radiant warmers; for information, see IEC 60601-2-21 [12]2; – incubators; for information, see IEC 60601-2-19 [10]; – transport incubators, for information, see IEC 60601-2-20 [11]; – cooling devices. 2) Figures in square brackets refer to the Bibliography.
URI: http://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/235855
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (2.666Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEC 80601-2-35

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2017-10-18T11:09:56Z
date available2017-10-18T11:09:56Z
date copyright2016.04.01
date issued2016
identifier otherXGJZOFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/235855
description abstractScope: Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HEATING DEVICES using BLANKETS, PADS or MATTRESSES in medical use, also referred to as ME EQUIPMENT. HEATING DEVICES intended to prewarm a bed are included in the scope of this International Standard. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. If a clause or subclause is specifically intended to apply to a specifically defined type of ME EQUIPMENT, as is the case with FORCED AIR DEVICES, then the clause or subclause is entitled as such. Clauses or subclauses that apply to all types of ME EQUIPMENT within the scope of this standard are not specifically entitled. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard does not apply to: – HEATING DEVICES intended for physiotherapy; – radiant warmers; for information, see IEC 60601-2-21 [12]2; – incubators; for information, see IEC 60601-2-19 [10]; – transport incubators, for information, see IEC 60601-2-20 [11]; – cooling devices. 2) Figures in square brackets refer to the Bibliography.
languageEnglish, French
titleIEC 80601-2-35num
titleEnglish -- Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads or mattresses and intended for heating in medical use - Edition 2.1; Consolidated Reprinten
titleFrench -- Appareils ‚lectrom‚dicaux ? Partie 2-35: Exigences particuliŠres pour la s‚curit‚ de base et les performances essentielles des dispositifs de r‚chauffage utilisant des couvertures, des coussins ou des matelas chauffants et destin‚s au r‚chauffage des patients en usage m‚dical - Edition 2.1; Consolidated Reprintother
typestandard
page290
statusActive
treeIEC - International Electrotechnical Commission:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian