IEC 61084-2-2
English -- Cable trunking systems and cable ducting systems for electrical installations - Part 2-2: Particular requirements - Cable trunking systems and cable ducting systems intended for mounting underfloor, flushfloor, or onfloor - Edition 2.0;
French -- SystŠmes de goulottes et systŠmes de conduits-profil‚s pour installations ‚lectriques - Partie 2-2: Exigences particuliŠres - SystŠmes de goulottes et systŠmes de conduits-profil‚s pr‚vus pour ˆtre mont‚s en sous-sol, encastr‚s dans le sol, ou sur le sol - Edition 2.0
Organization:
IEC - International Electrotechnical Commission
Year: 2017
Abstract: Scope: This part of the IEC 61084 series specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC. These systems are intended for mounting underfloor, flushfloor or onfloor. This document does not apply to CTS/CDS which are intended to be fixed to the wall and supported by the floor. This document does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards.
Collections
:
Show full item record
| contributor author | IEC - International Electrotechnical Commission | |
| date accessioned | 2017-10-18T11:12:46Z | |
| date available | 2017-10-18T11:12:46Z | |
| date copyright | 2017.03.01 | |
| date issued | 2017 | |
| identifier other | DJQHYFAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/236540 | |
| description abstract | Scope: This part of the IEC 61084 series specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC. These systems are intended for mounting underfloor, flushfloor or onfloor. This document does not apply to CTS/CDS which are intended to be fixed to the wall and supported by the floor. This document does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. | |
| language | English, French | |
| title | IEC 61084-2-2 | num |
| title | English -- Cable trunking systems and cable ducting systems for electrical installations - Part 2-2: Particular requirements - Cable trunking systems and cable ducting systems intended for mounting underfloor, flushfloor, or onfloor - Edition 2.0 | en |
| title | French -- SystŠmes de goulottes et systŠmes de conduits-profil‚s pour installations ‚lectriques - Partie 2-2: Exigences particuliŠres - SystŠmes de goulottes et systŠmes de conduits-profil‚s pr‚vus pour ˆtre mont‚s en sous-sol, encastr‚s dans le sol, ou sur le sol - Edition 2.0 | other |
| type | standard | |
| page | 66 | |
| status | Active | |
| tree | IEC - International Electrotechnical Commission:;2017 | |
| contenttype | fulltext |

درباره ما