IEC 61558-1 (REDLINE + STANDARD)

Safety of transformers, reactors, power supply units and combinations thereof – Part 1: General requirements and tests - Edition 3.0

Organization:
IEC - International Electrotechnical Commission
Year: 2017

Abstract: This part of IEC 61558 deals with safety aspects of transformers, reactors, power supply units and combinations thereof such as electrical, thermal and mechanical safety This document covers the following independent or associated stationary or portable types of dry-type transformers, power supply units, including switch mode power supply units, reactors and combinations thereof in the field of safety. The windings can be encapsulated or non-encapsulated. They are not forming a part of the distribution network NOTE 1 The distinction between transformers, power supply units and switch mode power supply units is as follows for transformers, there is no change in frequency. However, transformers (e.g. constant voltage transformers) can have an internal resonance frequency not exceeding 30 kHz for power supply units, the internal operational frequency and waveform are different from the supply frequency and waveform, and the internal operational frequency does not exceed 500 Hz (see definition 3.1.19) for switch mode power supply units, the internal operational frequency and waveform are different from the supply frequency and waveform and the internal operational frequency exceeds 500 Hz and does not exceed 100 MHz The relevant parts of IEC 61558-2 can be found in the introduction of this document
URI: http://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264268
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (7.182Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEC 61558-1 (REDLINE + STANDARD)

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:57:54Z
date available2018-07-31T09:57:54Z
date copyright2017.09.01
date issued2017
identifier otherENHICGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264268
description abstractThis part of IEC 61558 deals with safety aspects of transformers, reactors, power supply units and combinations thereof such as electrical, thermal and mechanical safety This document covers the following independent or associated stationary or portable types of dry-type transformers, power supply units, including switch mode power supply units, reactors and combinations thereof in the field of safety. The windings can be encapsulated or non-encapsulated. They are not forming a part of the distribution network NOTE 1 The distinction between transformers, power supply units and switch mode power supply units is as follows for transformers, there is no change in frequency. However, transformers (e.g. constant voltage transformers) can have an internal resonance frequency not exceeding 30 kHz for power supply units, the internal operational frequency and waveform are different from the supply frequency and waveform, and the internal operational frequency does not exceed 500 Hz (see definition 3.1.19) for switch mode power supply units, the internal operational frequency and waveform are different from the supply frequency and waveform and the internal operational frequency exceeds 500 Hz and does not exceed 100 MHz The relevant parts of IEC 61558-2 can be found in the introduction of this document
languageEnglish
titleIEC 61558-1 (REDLINE + STANDARD)num
titleSafety of transformers, reactors, power supply units and combinations thereof – Part 1: General requirements and tests - Edition 3.0en
typestandard
page560
statusActive
treeIEC - International Electrotechnical Commission:;2017
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian