IEC 60772

|French -- Centrales nucléaires de puissance – Systèmes d’instrumentation importants pour la sûreté – Ensembles de traversée électrique dans les structures de confinement - Edition 2.0Nuclear power plants – Instrumentation systems important to safety – El

Organization:
IEC - International Electrotechnical Commission
Year: 2018

Abstract: This document applies to electrical penetration assemblies (EPAs) in containment structures of nuclear power plants. It covers the engineering safety requirements to be met in the design, calculation, qualification, fabrication, assembly, testing, and installation of EPAs. EPAs provide gas-tight and pressure-resistant penetrations through the containment for one or more electrical circuits. EPA requirements are divided into mechanical (e.g. containment integrity), and electrical or optical aspects regarding safety. The mechanical requirements are valid for all EPAs. The electrical or optical requirements are derived from the functional requirements of the connected systems, applied for monitoring and mitigating postulated events such as design basis events (DBE; e.g. loss of coolant accidents) and/or design extension conditions (DEC; e.g. severe accidents). EPAs are distinguished by the type of electrical or optical circuit in which they are used. The derived types of EPAs are identified as follows: • medium voltage power, • low voltage power, • control, • instrumentation, and • fibre optic. For the purpose of this document, EPAs include: • electrical conductors up to the connection interface inside and outside the containment (penetration conductors); • the electrical insulation systems of penetration conductors including the electrical insulation of the connection interface; • components for the resistance to environmental conditions, such as pressure resistance, gas tightness, temperature resistance, radiations resistance, seismic resistance enclosure of this EPA, and for connection with the containment wall; • if required, permanently connected equipment for leak tightness monitoring; • standard electrical connection interfaces such as cable lugs, terminals, and connectors; • terminals and/or junction boxes (if necessary). The components, which are not part of an EPA, include: • components of the containment wall for the attachment of the EPA, such as sealing surfaces for bolting, or pipe connections, or nozzles requiring welding; • cables and wires connected to the EPA conductors or connectors; • terminal elements such as cable lugs, terminals, connectors or soldering sleeves attached to the cables and lines connected; • leak test or evacuation devices connected temporarily to penetrations; • the requirements for external circuits, connected to the EPA or the containment structure. This document does not cover requirements for EPAs regarding operation and maintenance.
URI: http://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264329
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (1.490Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEC 60772

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:58:02Z
date available2018-07-31T09:58:02Z
date copyright2018.05.01
date issued2018
identifier otherGLTDFGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264329
description abstractThis document applies to electrical penetration assemblies (EPAs) in containment structures of nuclear power plants. It covers the engineering safety requirements to be met in the design, calculation, qualification, fabrication, assembly, testing, and installation of EPAs. EPAs provide gas-tight and pressure-resistant penetrations through the containment for one or more electrical circuits. EPA requirements are divided into mechanical (e.g. containment integrity), and electrical or optical aspects regarding safety. The mechanical requirements are valid for all EPAs. The electrical or optical requirements are derived from the functional requirements of the connected systems, applied for monitoring and mitigating postulated events such as design basis events (DBE; e.g. loss of coolant accidents) and/or design extension conditions (DEC; e.g. severe accidents). EPAs are distinguished by the type of electrical or optical circuit in which they are used. The derived types of EPAs are identified as follows: • medium voltage power, • low voltage power, • control, • instrumentation, and • fibre optic. For the purpose of this document, EPAs include: • electrical conductors up to the connection interface inside and outside the containment (penetration conductors); • the electrical insulation systems of penetration conductors including the electrical insulation of the connection interface; • components for the resistance to environmental conditions, such as pressure resistance, gas tightness, temperature resistance, radiations resistance, seismic resistance enclosure of this EPA, and for connection with the containment wall; • if required, permanently connected equipment for leak tightness monitoring; • standard electrical connection interfaces such as cable lugs, terminals, and connectors; • terminals and/or junction boxes (if necessary). The components, which are not part of an EPA, include: • components of the containment wall for the attachment of the EPA, such as sealing surfaces for bolting, or pipe connections, or nozzles requiring welding; • cables and wires connected to the EPA conductors or connectors; • terminal elements such as cable lugs, terminals, connectors or soldering sleeves attached to the cables and lines connected; • leak test or evacuation devices connected temporarily to penetrations; • the requirements for external circuits, connected to the EPA or the containment structure. This document does not cover requirements for EPAs regarding operation and maintenance.
languageEnglish
languageFrench
titleIEC 60772num
title|French -- Centrales nucléaires de puissance – Systèmes d’instrumentation importants pour la sûreté – Ensembles de traversée électrique dans les structures de confinement - Edition 2.0Nuclear power plants – Instrumentation systems important to safety – Elen
typestandard
page88
statusActive
treeIEC - International Electrotechnical Commission:;2018
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian