IEC 62359

Ultrasonics – Field characterization – Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields - Edition 2.1; Consolidated Reprint

Organization:
IEC - International Electrotechnical Commission
Year: 2017

Abstract: This International standard is applicable to medical diagnostic ultrasound fields. This standard establishes – parameters related to thermal and non-thermal exposure aspects of diagnostic ultrasonic fields; – methods for the determination of an exposure parameter relating to temperature rise in theoretical tissue-equivalent models, resulting from absorption of ultrasound; – methods for the determination of an exposure parameter appropriate to certain nonthermal effects. NOTE 1 In Clause 3 of this standard, SI units are used (per ISO/IEC Directives, Part 2, ed. 5, Annex I b) in the Notes below definitions of certain parameters, such as beam areas and intensities; it may be convenient to use decimal multiples or submultiples in practice. Users must take care of decimal prefixes used in combination with the units when using and calculating numerical data. For example, beam area may be specified in cm2 and intensities in W/cm2 or mW/cm2. NOTE 2 Underlying calculations have been done from 0,25 MHz to 15 MHz for MI and 0,5 MHz to 15 MHz for TI. NOTE 3 The thermal indices are steady state estimates based on the acoustic output power required to produce a 1°C temperature rise in tissue conforming to the “homogeneous tissue 0,3 dBcm-1MHz-1 attenuation model” [1 ] 1) and may not be appropriate for radiation force imaging, or similar techniques that employ pulses or pulse bursts of sufficient duration to create a significant transient temperature rise. [2]
URI: http://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264361
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (3.005Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEC 62359

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:58:05Z
date available2018-07-31T09:58:05Z
date copyright2017.09.01
date issued2017
identifier otherHNHICGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264361
description abstractThis International standard is applicable to medical diagnostic ultrasound fields. This standard establishes – parameters related to thermal and non-thermal exposure aspects of diagnostic ultrasonic fields; – methods for the determination of an exposure parameter relating to temperature rise in theoretical tissue-equivalent models, resulting from absorption of ultrasound; – methods for the determination of an exposure parameter appropriate to certain nonthermal effects. NOTE 1 In Clause 3 of this standard, SI units are used (per ISO/IEC Directives, Part 2, ed. 5, Annex I b) in the Notes below definitions of certain parameters, such as beam areas and intensities; it may be convenient to use decimal multiples or submultiples in practice. Users must take care of decimal prefixes used in combination with the units when using and calculating numerical data. For example, beam area may be specified in cm2 and intensities in W/cm2 or mW/cm2. NOTE 2 Underlying calculations have been done from 0,25 MHz to 15 MHz for MI and 0,5 MHz to 15 MHz for TI. NOTE 3 The thermal indices are steady state estimates based on the acoustic output power required to produce a 1°C temperature rise in tissue conforming to the “homogeneous tissue 0,3 dBcm-1MHz-1 attenuation model” [1 ] 1) and may not be appropriate for radiation force imaging, or similar techniques that employ pulses or pulse bursts of sufficient duration to create a significant transient temperature rise. [2]
languageEnglish
languageFrench
titleIEC 62359num
titleUltrasonics – Field characterization – Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields - Edition 2.1; Consolidated Reprinten
typestandard
page176
statusActive
treeIEC - International Electrotechnical Commission:;2017
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian