IEC TS 63014-1

High voltage direct current (HVDC) power transmission – System requirements for DC-side equipment Part 1: Using line-commutated converters - Edition 1.0

Organization:
IEC - International Electrotechnical Commission
Year: 2018

Abstract: This Technical Specification is intended to provide an overall and consistent set of guidelines to facilitate the specification of equipment for the DC-side of a high-voltage direct current (HVDC) system using line-commutated converters. For point-to-point HVDC transmission systems, this document covers all DC-side equipment located between the converter valves and the DC overhead line or cable termination, excluding the converter valves themselves. For back-to-back HVDC systems, this document covers all DC-side equipment excluding the converter valves themselves. Throughout this publication, the terms \'direct voltage\' and \'DC voltage\' are used interchangeably, as are \'direct current\' and \'DC current\'. Traditionally, the largest items of such equipment, such as the DC smoothing reactor and DC harmonic filters, have generally been located outdoors but increasingly the trend is to locate such equipment indoors (although not in the valve hall itself) to provide protection from pollution. Although product standards exist for some DC-side equipment types, many such items of equipment have only standards written for AC applications and, in such cases, the purpose of this document is to provide guidance as to how to specify the additional requirements (particularly with regard to testing) for such equipment to cover their use in DC conditions. The converter itself is excluded from this scope, being covered by IEC 60700-1 [1] 1 and IEC 60700-2 [2]. Although this document includes requirements for DC disconnectors and certain types of specialised DC switching devices (such as the Metallic Return Transfer Switch (MRTS)), it excludes any type of DC circuit-breaker designed to interrupt fault currents. DC-side equipment for HVDC systems based on voltage-sourced converter (VSC) technology is excluded from this document and will be covered in a future Part 2 of IEC 63014. 1 Numbers in square brackets refer to the Bibliography.        
URI: http://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264393
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (1.977Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEC TS 63014-1

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:58:08Z
date available2018-07-31T09:58:08Z
date copyright2018.03.01
date issued2018
identifier otherIJCWEGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264393
description abstractThis Technical Specification is intended to provide an overall and consistent set of guidelines to facilitate the specification of equipment for the DC-side of a high-voltage direct current (HVDC) system using line-commutated converters. For point-to-point HVDC transmission systems, this document covers all DC-side equipment located between the converter valves and the DC overhead line or cable termination, excluding the converter valves themselves. For back-to-back HVDC systems, this document covers all DC-side equipment excluding the converter valves themselves. Throughout this publication, the terms \'direct voltage\' and \'DC voltage\' are used interchangeably, as are \'direct current\' and \'DC current\'. Traditionally, the largest items of such equipment, such as the DC smoothing reactor and DC harmonic filters, have generally been located outdoors but increasingly the trend is to locate such equipment indoors (although not in the valve hall itself) to provide protection from pollution. Although product standards exist for some DC-side equipment types, many such items of equipment have only standards written for AC applications and, in such cases, the purpose of this document is to provide guidance as to how to specify the additional requirements (particularly with regard to testing) for such equipment to cover their use in DC conditions. The converter itself is excluded from this scope, being covered by IEC 60700-1 [1] 1 and IEC 60700-2 [2]. Although this document includes requirements for DC disconnectors and certain types of specialised DC switching devices (such as the Metallic Return Transfer Switch (MRTS)), it excludes any type of DC circuit-breaker designed to interrupt fault currents. DC-side equipment for HVDC systems based on voltage-sourced converter (VSC) technology is excluded from this document and will be covered in a future Part 2 of IEC 63014. 1 Numbers in square brackets refer to the Bibliography.        
languageEnglish
titleIEC TS 63014-1num
titleHigh voltage direct current (HVDC) power transmission – System requirements for DC-side equipment Part 1: Using line-commutated converters - Edition 1.0en
typestandard
page92
statusActive
treeIEC - International Electrotechnical Commission:;2018
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian