CSA CAN/CSA-C22.2 NO. 60601-1-3-09

English -- Medical electrical equipment — Part 1-3: General requirements for basic safety and essential performance — Collateral Standard: Radiation protection in diagnostic X-ray equipment - Second Edition;
French -- Appareils électromédicaux — Partie 1-3 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Radioprotection dans les appareils à rayonnement X de diagnostic - Second Edition

Organization:
CSA - CSA Group
Year: 2009

Abstract: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS.
This collateral standard applies to X-RAY EQUIPMENT and to sub-assemblies of such equipment, where RADIOLOGICAL IMAGES of a human PATIENT are used for diagnosis, planning or guidance of medical procedures.
Object
The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards.
The object of this collateral standard is to establish general requirements for protection against X-RADIATION in X-RAY EQUIPMENT, in order that the IRRADIATION of the human PATIENT, the OPERATOR, staff and members of the public can be kept as low as reasonably achievable, without jeopardizing the benefit of the RADIOLOGICAL procedure. Particular standards may specify their appropriate values and/or measures for general requirements specified in this collateral standard. The implementation of the general requirements or the reference to the particular standard instead, shall be justified in the RISK MANAGEMENT process.
This collateral standard considers RADIATION PROTECTION aspects related to X-RADIATION only.
Requirements for the control of the electrical energy used to generate X-RADIATION, which is also an important aspect of RADIATION PROTECTION, are included in IEC 60601-1 and in particular standards for the safety and ESSENTIAL PERFORMANCE of the EQUIPMENT concerned.
URI: http://yse.yabesh.ir/std;quein=a/handle/yse/221894
Collections :
  • CSA - CSA Group
  • Download PDF : (1.304Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA CAN/CSA-C22.2 NO. 60601-1-3-09

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:40:18Z
date available2017-09-04T18:40:18Z
date copyright2009.11.01
date issued2009
identifier otherJUGHPCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;quein=a/handle/yse/221894
description abstractThis International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS.
This collateral standard applies to X-RAY EQUIPMENT and to sub-assemblies of such equipment, where RADIOLOGICAL IMAGES of a human PATIENT are used for diagnosis, planning or guidance of medical procedures.
Object
The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards.
The object of this collateral standard is to establish general requirements for protection against X-RADIATION in X-RAY EQUIPMENT, in order that the IRRADIATION of the human PATIENT, the OPERATOR, staff and members of the public can be kept as low as reasonably achievable, without jeopardizing the benefit of the RADIOLOGICAL procedure. Particular standards may specify their appropriate values and/or measures for general requirements specified in this collateral standard. The implementation of the general requirements or the reference to the particular standard instead, shall be justified in the RISK MANAGEMENT process.
This collateral standard considers RADIATION PROTECTION aspects related to X-RADIATION only.
Requirements for the control of the electrical energy used to generate X-RADIATION, which is also an important aspect of RADIATION PROTECTION, are included in IEC 60601-1 and in particular standards for the safety and ESSENTIAL PERFORMANCE of the EQUIPMENT concerned.
languageEnglish, French
titleCSA CAN/CSA-C22.2 NO. 60601-1-3-09num
titleEnglish -- Medical electrical equipment — Part 1-3: General requirements for basic safety and essential performance — Collateral Standard: Radiation protection in diagnostic X-ray equipment - Second Editionen
titleFrench -- Appareils électromédicaux — Partie 1-3 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Radioprotection dans les appareils à rayonnement X de diagnostic - Second Editionother
typestandard
page124
statusActive
treeCSA - CSA Group:;2009
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian