ECA EIA-364-78B

TP-78B CAVITY-TO-CAVITY LEAKAGE BONDING INTEGRITY TEST PROCEDURE FOR ELECTRICAL CONNECTORS

Organization:
ECIA - Electronic Components Industry Association
Year: 2010

Abstract: This standard establishes a technique for evaluating the sealing integrity of the contact cavity walls of an environmentally sealed electrical connector by detecting leakage between a given contact cavity and those adjacent to it. This technique is suitable for application at the onset of a series of environmental tests (e.g., qualification or periodic inspection) to evaluate the soundness of the product before the start of test.
URI: http://yse.yabesh.ir/std;query=anid=47037D83081DAC4218546D6E273C9FCD/handle/yse/40255
Collections :
  • ECIA - Electronic Components Industry Association
  • Download PDF : (285.3Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ECA EIA-364-78B

Show full item record

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T15:38:13Z
date available2017-09-04T15:38:13Z
date copyright40483
date issued2010
identifier otherOXLUEDAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=anid=47037D83081DAC4218546D6E273C9FCD/handle/yse/40255
description abstractThis standard establishes a technique for evaluating the sealing integrity of the contact cavity walls of an environmentally sealed electrical connector by detecting leakage between a given contact cavity and those adjacent to it. This technique is suitable for application at the onset of a series of environmental tests (e.g., qualification or periodic inspection) to evaluate the soundness of the product before the start of test.
languageEnglish
titleECA EIA-364-78Bnum
titleTP-78B CAVITY-TO-CAVITY LEAKAGE BONDING INTEGRITY TEST PROCEDURE FOR ELECTRICAL CONNECTORSen
typestandard
page12
statusActive
treeECIA - Electronic Components Industry Association:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian