• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • ECIA - Electronic Components Industry Association
  • View Item
  •   YSE
  • Industrial Standards
  • ECIA - Electronic Components Industry Association
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

ECA IS-722

Low-Voltage Supplemental Fuse Qualification Specification

Organization:
ECIA - Electronic Components Industry Association
Year: 1997

Abstract: Description
This specification defines the qualification program for low voltage, supplemental fuses. Fuses covered will be limited to axial-leaded, radial-leaded and surface mount configurations having a current rating of no greater than 60 A, maximum voltage rating of 600 VAC/DC and interrupting rating of 10,000 A maximum. The qualification program is defined in table 1, and the flow diagram. Specification sheets can be added, as required, to define specific products or to cover unique / specific requirements. This document does not relieve the suppliers of their responsibility to maintain their own company's internal qualification program and the fuses shall continue to meet all applicable requirements of UL 248-14 / CSA-C22.2 NO. 248.14.
Three types of fuses are covered in this specification. They include:
Type I The type I fuse is designed to operate (open) within a given time period at 200% overload. The remainder of this specification is written with the 200% overload test used as the standard.
Type II The type II fuse is designed to operate (open) within a given time period at 250% overload. For a Type II fuse, the 250% overload shall be substituted throughout this specification where 200% overload is noted. All other requirements shall continue to be met.
Type III The type III fuse is designed to operate (open) within a given time period at 300% overload. For a Type III fuse, the 300% overload shall be substituted throughout this specification where 200% overload is noted. All other requirements shall continue to be met.
Preconditioning
This process is intended to simulate exposure to the thermal and cleaning environments of the assembly process before qualification testing. The component assembly process simulation requirements for different types of processes are described in annex A.
URI: http://yse.yabesh.ir/std;query=anid=47037D83081DAC4218546D6E273C9FCD/handle/yse/61680
Collections :
  • ECIA - Electronic Components Industry Association
  • Download PDF : (1.243Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ECA IS-722

Show full item record

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T15:58:33Z
date available2017-09-04T15:58:33Z
date copyright05/01/1997
date issued1997
identifier otherRCYYCAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=anid=47037D83081DAC4218546D6E273C9FCD/handle/yse/61680
description abstractDescription
This specification defines the qualification program for low voltage, supplemental fuses. Fuses covered will be limited to axial-leaded, radial-leaded and surface mount configurations having a current rating of no greater than 60 A, maximum voltage rating of 600 VAC/DC and interrupting rating of 10,000 A maximum. The qualification program is defined in table 1, and the flow diagram. Specification sheets can be added, as required, to define specific products or to cover unique / specific requirements. This document does not relieve the suppliers of their responsibility to maintain their own company's internal qualification program and the fuses shall continue to meet all applicable requirements of UL 248-14 / CSA-C22.2 NO. 248.14.
Three types of fuses are covered in this specification. They include:
Type I The type I fuse is designed to operate (open) within a given time period at 200% overload. The remainder of this specification is written with the 200% overload test used as the standard.
Type II The type II fuse is designed to operate (open) within a given time period at 250% overload. For a Type II fuse, the 250% overload shall be substituted throughout this specification where 200% overload is noted. All other requirements shall continue to be met.
Type III The type III fuse is designed to operate (open) within a given time period at 300% overload. For a Type III fuse, the 300% overload shall be substituted throughout this specification where 200% overload is noted. All other requirements shall continue to be met.
Preconditioning
This process is intended to simulate exposure to the thermal and cleaning environments of the assembly process before qualification testing. The component assembly process simulation requirements for different types of processes are described in annex A.
languageEnglish
titleECA IS-722num
titleLow-Voltage Supplemental Fuse Qualification Specificationen
typestandard
page31
statusActive
treeECIA - Electronic Components Industry Association:;1997
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian