Safe limits for operating voltages and currents of telecommunication systems powered over the network

ITU-T K.50 (07/2016)

Organization:
ITU-T - International Telecommunication Union/ITU Telcommunication Sector
Year: 2016

Abstract: This Recommendation provides guidance on voltages and currents that may safely be used to power telecommunication systems that are part of the telecommunications service providers’ network. These systems use the paired-conductor cables of the network or specific power feeding cables to provide power to equipment at remote locations. This equipment and the current carrying conductors can be accessed in the energized state by service or skilled personnel without using insulated gloves or tools. For safety reasons, system types operating at hazardous voltages are not intended to pass beyond the public network interface between the service provider and the end customer. These hazardous voltage systems are not intended to be part of the subscriber's installation, and are not accessible to users of the network. They are located in the networks between different telecommunication centres, between a telecommunication centre and a telecommunications access facility/node, and between a telecommunication centre and public network interfaces. This Recommendation covers only systems that use continuous dc powering.
URI: http://yse.yabesh.ir/std;query=autho109sear79D40527318548F1EFDEC014A/handle/yse/251655
Collections :
  • ITU-T - International Telecommunication Union/ITU Telcommunication Sector
  • Download PDF : (854.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Safe limits for operating voltages and currents of telecommunication systems powered over the network

Show full item record

contributor authorITU-T - International Telecommunication Union/ITU Telcommunication Sector
date accessioned2017-11-25T08:07:53Z
date available2017-11-25T08:07:53Z
date copyright2016-07-14
date issued2016
identifier otherT-REC-K.50-201607-S!!PDF-E.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho109sear79D40527318548F1EFDEC014A/handle/yse/251655
description abstractThis Recommendation provides guidance on voltages and currents that may safely be used to power telecommunication systems that are part of the telecommunications service providers’ network. These systems use the paired-conductor cables of the network or specific power feeding cables to provide power to equipment at remote locations. This equipment and the current carrying conductors can be accessed in the energized state by service or skilled personnel without using insulated gloves or tools. For safety reasons, system types operating at hazardous voltages are not intended to pass beyond the public network interface between the service provider and the end customer. These hazardous voltage systems are not intended to be part of the subscriber's installation, and are not accessible to users of the network. They are located in the networks between different telecommunication centres, between a telecommunication centre and a telecommunications access facility/node, and between a telecommunication centre and public network interfaces. This Recommendation covers only systems that use continuous dc powering.
languageEnglish
titleSafe limits for operating voltages and currents of telecommunication systems powered over the networken
titleITU-T K.50 (07/2016)num
typestandard
statusSuperseded
treeITU-T - International Telecommunication Union/ITU Telcommunication Sector:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian