Methods of Testing Capacity of Refrigerant Solenoid Valves

ASHRAE 158.1

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2019

Abstract: This standard is applicable to refrigerant solenoid valves in the following circumstances: a. As defined in Section 3, "Definitions" b. For either liquid or vapor refrigerant applications c. For use with refrigerants deemed available and suitable according to ANSI/ASHRAE Standard 15, Safety Standard for Refrigeration Systems1, and ANSI/ASHRAE Standard 342, Designation and Safety Classification of Refrigerants. This standard specifies procedures, apparatus, and instrumentation that will produce accurate capacity data. This standard does not do the following: a. Specify rating conditions or electrical or mechanical design requirements (Rating conditions may be found in ANSI/AHRI Standard 760, Performance Rating of Solenoid Valves for Use with Volatile Refrigerants3, for I-P units, or ANSI/AHRI Standards 761, Performance Rating of Solenoid Valves for Use with Volatile Refrigeratants4, for SI units.) b. Make recommendations for safety c. Specify tests for production, specification compliance, or field testing of solenoid valves PURPOSE This standard prescribes a method of testing the capacity of refrigerant solenoid valves for use in refrigerating systems. 1 ASHRAE. 2016. ANSI/ASHRAE Standard 15, Safety Standard for Refrigeration Systems. Atlanta:ASHRAE. 2 ASHRAE. 2016. ANSI/ASHRAE Standard 34, Designation and Safety Classification of refrigerants. Atlanta:ASHRAE. 3 AHRI. 2014. ANSI/AHRI Standard 760 (I-P), Performance Rating of Solenoid Valves for Use with Volatile Refrigerants. Arlington, VA: Air-Conditioning, Heating, and Refrigeration Institute. 4 AHRI. 2014. ANSI/AHRI Standard 761 (SI), Performance Rating of Solenoid Valves for Use with Volatile Refrigerants. Arlington, VA: Air-Conditioning, Heating, and Refrigeration Institute
URI: http://yse.yabesh.ir/std;query=autho162/handle/yse/280399
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (518.0Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Methods of Testing Capacity of Refrigerant Solenoid Valves

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2020-07-27T20:51:08Z
date available2020-07-27T20:51:08Z
date issued2019
identifier otherJZYAIGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho162/handle/yse/280399
description abstractThis standard is applicable to refrigerant solenoid valves in the following circumstances: a. As defined in Section 3, "Definitions" b. For either liquid or vapor refrigerant applications c. For use with refrigerants deemed available and suitable according to ANSI/ASHRAE Standard 15, Safety Standard for Refrigeration Systems1, and ANSI/ASHRAE Standard 342, Designation and Safety Classification of Refrigerants. This standard specifies procedures, apparatus, and instrumentation that will produce accurate capacity data. This standard does not do the following: a. Specify rating conditions or electrical or mechanical design requirements (Rating conditions may be found in ANSI/AHRI Standard 760, Performance Rating of Solenoid Valves for Use with Volatile Refrigerants3, for I-P units, or ANSI/AHRI Standards 761, Performance Rating of Solenoid Valves for Use with Volatile Refrigeratants4, for SI units.) b. Make recommendations for safety c. Specify tests for production, specification compliance, or field testing of solenoid valves PURPOSE This standard prescribes a method of testing the capacity of refrigerant solenoid valves for use in refrigerating systems. 1 ASHRAE. 2016. ANSI/ASHRAE Standard 15, Safety Standard for Refrigeration Systems. Atlanta:ASHRAE. 2 ASHRAE. 2016. ANSI/ASHRAE Standard 34, Designation and Safety Classification of refrigerants. Atlanta:ASHRAE. 3 AHRI. 2014. ANSI/AHRI Standard 760 (I-P), Performance Rating of Solenoid Valves for Use with Volatile Refrigerants. Arlington, VA: Air-Conditioning, Heating, and Refrigeration Institute. 4 AHRI. 2014. ANSI/AHRI Standard 761 (SI), Performance Rating of Solenoid Valves for Use with Volatile Refrigerants. Arlington, VA: Air-Conditioning, Heating, and Refrigeration Institute
languageEnglish
titleMethods of Testing Capacity of Refrigerant Solenoid Valvesen
titleASHRAE 158.1num
typestandard
page18
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2019
contenttypefulltext