Energy Standard for Buildings Except Low-Rise Residential Buildings
ASHRAE 90.1-2019 I-P ERTA
Year: 2020
Abstract: The corrections listed in this errata sheet apply to ANSI/ASHRAE/IES Standard 90.1-2019, I-P Edition.
The first printing is identified on the outside back cover of the standard as “Product code: 86270 10/19”.
Shaded items have been added since the previously published errata sheet dated March 18, 2020 was distributed.
ASHRAE now has a list server for Standing Standards Project Committee 90.1 (SSPC 90.1).
Interested parties can now subscribe and unsubscribe to the list server and be automatically notified via e-mail when activities and information related to the Standard and the User’s Manual is available.
To sign up for the list server please visit Project Committee List Servers for Standard on the Technology / Standards section of the ASHRAE website at https://www.ashrae.org/technical-resources/standards-and-guidelines/project-committee-list- servers.
the difference between the dry bulb air temperatures leaving the series energy recovery unit and leaving the dehumidifying coil divided by the difference between 75˚F and the dry bulb temperature of the air leaving the dehumidifying cooling coil
-
Statistics
Energy Standard for Buildings Except Low-Rise Residential Buildings
Show full item record
contributor author | ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. | |
date accessioned | 2020-08-03T11:59:55Z | |
date available | 2020-08-03T11:59:55Z | |
date issued | 2020 | |
identifier other | LLTPMGAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;query=autho162/handle/yse/280669 | |
description abstract | The corrections listed in this errata sheet apply to ANSI/ASHRAE/IES Standard 90.1-2019, I-P Edition. The first printing is identified on the outside back cover of the standard as “Product code: 86270 10/19”. Shaded items have been added since the previously published errata sheet dated March 18, 2020 was distributed. ASHRAE now has a list server for Standing Standards Project Committee 90.1 (SSPC 90.1). Interested parties can now subscribe and unsubscribe to the list server and be automatically notified via e-mail when activities and information related to the Standard and the User’s Manual is available. To sign up for the list server please visit Project Committee List Servers for Standard on the Technology / Standards section of the ASHRAE website at https://www.ashrae.org/technical-resources/standards-and-guidelines/project-committee-list- servers. the difference between the dry bulb air temperatures leaving the series energy recovery unit and leaving the dehumidifying coil divided by the difference between 75˚F and the dry bulb temperature of the air leaving the dehumidifying cooling coil | |
language | English | |
title | Energy Standard for Buildings Except Low-Rise Residential Buildings | en |
title | ASHRAE 90.1-2019 I-P ERTA | num |
type | standard | |
page | 16 | |
status | Active | |
tree | ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2020 | |
contenttype | fulltext |