MIL-HDBK-1264

RADIOGRAPHIC INSPECTION FOR SOUNDNESS OF WELDS IN STEEL BY COMPARSION TO GRADED ASTM E390 REFERENCE RADIOGRAPHS

Organization:
ARMY - MR - Army Research Laboratory, Weapons and Materials Research Directorate
Year: 1998

Abstract: This handbook prescribes requirements for radiographic inspection for soundness of welds in steel by comparison to selective severity levels of ASTM E390, Volume II reference radiographs. The base material varies from greater that 0.25 to 3.0 in. (6.4 to 76 mm) inclusive in thickness. This handbook is not suitable for shipyard use. This handbook is for guidance only. This handbook cannot be cited as a requirement. If it is, the contractor does not have to comply. Intended Use: This handbook is to be used as a guide when comparing radiographic inspection for soundness of welds in steel to selected severity levels of reference radiographs provided in an ASTM standard.
URI: http://yse.yabesh.ir/std;query=autho1626AF679D40527318549F1EFDEC014A/handle/yse/68581
Subject: Crater crack
Collections :
  • ARMY - MR - Army Research Laboratory, Weapons and Materials Research Directorate
  • Download PDF : (35.15Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-HDBK-1264

Show full item record

contributor authorARMY - MR - Army Research Laboratory, Weapons and Materials Research Directorate
date accessioned2017-09-04T16:05:23Z
date available2017-09-04T16:05:23Z
date copyright08/17/1998
date issued1998
identifier otherRVSBEAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho1626AF679D40527318549F1EFDEC014A/handle/yse/68581
description abstractThis handbook prescribes requirements for radiographic inspection for soundness of welds in steel by comparison to selective severity levels of ASTM E390, Volume II reference radiographs. The base material varies from greater that 0.25 to 3.0 in. (6.4 to 76 mm) inclusive in thickness. This handbook is not suitable for shipyard use. This handbook is for guidance only. This handbook cannot be cited as a requirement. If it is, the contractor does not have to comply. Intended Use: This handbook is to be used as a guide when comparing radiographic inspection for soundness of welds in steel to selected severity levels of reference radiographs provided in an ASTM standard.
languageEnglish
titleMIL-HDBK-1264num
titleRADIOGRAPHIC INSPECTION FOR SOUNDNESS OF WELDS IN STEEL BY COMPARSION TO GRADED ASTM E390 REFERENCE RADIOGRAPHSen
typestandard
page10
statusActive
treeARMY - MR - Army Research Laboratory, Weapons and Materials Research Directorate:;1998
contenttypefulltext
subject keywordsCrater crack
subject keywordsDiscontinuities
subject keywordsPorosity
subject keywordsTungsten inclusions