Standard Practice for Collection of Integrated Samples for the Speciation of Biomass (Biogenic) and Fossil-Derived Carbon Dioxide Emitted from Stationary Emissions Sources

ASTM D7459-25

Organization:
ASTM - ASTM International
Year: 2025

Abstract: 5.1 Greenhouse gases are reported to be a major contributor to global warming. Since “biomass CO2” emitted from combustion devices represents a net-zero carbon contribution to the atmosphere (that is, plants remove CO2 from the atmosphere and subsequent combustion returns it), it does not contribute additional CO2 to the atmosphere. The measurement of biomass (biogenic) CO2 allows regulators and stationary source owners/operators to determine the ratio of fossil-derived CO2 and biomass CO2 in developing control strategies and to meet federal, state, local and regional greenhouse gas reporting requirements. 5.2 The distinction of the two types of CO2 has financial, control and regulatory implications.
URI: http://yse.yabesh.ir/std;query=autho162sAF679D/handle/yse/343702
Collections :
  • ASTM - ASTM International
  • Download PDF : (322.8Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Practice for Collection of Integrated Samples for the Speciation of Biomass (Biogenic) and Fossil-Derived Carbon Dioxide Emitted from Stationary Emissions Sources

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T19:27:50Z
date available2025-09-30T19:27:50Z
date copyright2025
date issued2025
identifier otherd7459-25.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho162sAF679D/handle/yse/343702
description abstract5.1 Greenhouse gases are reported to be a major contributor to global warming. Since “biomass CO2” emitted from combustion devices represents a net-zero carbon contribution to the atmosphere (that is, plants remove CO2 from the atmosphere and subsequent combustion returns it), it does not contribute additional CO2 to the atmosphere. The measurement of biomass (biogenic) CO2 allows regulators and stationary source owners/operators to determine the ratio of fossil-derived CO2 and biomass CO2 in developing control strategies and to meet federal, state, local and regional greenhouse gas reporting requirements. 5.2 The distinction of the two types of CO2 has financial, control and regulatory implications.
languageEnglish
titleStandard Practice for Collection of Integrated Samples for the Speciation of Biomass (Biogenic) and Fossil-Derived Carbon Dioxide Emitted from Stationary Emissions Sourcesen
titleASTM D7459-25num
typestandard
statusActive
treeASTM - ASTM International:;2025
contenttypefulltext
scope1.1 This practice defines specific procedures for the collection of gas samples from stationary emission sources for subsequent laboratory determination of the ratio of biomass (biogenic) carbon to total carbon (fossil derived carbon plus biomass or biogenic carbon) in accordance with Test Methods D6866. 1.2 This practice applies to stationary sources that burn municipal solid waste or a combination of fossil fuel (for example, coal, oil, natural gas) and biomass fuel (for example, wood, wood waste, paper, agricultural waste, biogas) in boilers, combustion turbines, incinerators, kilns, internal combustion engines and other combustion devices. 1.3 This practice applies to the collection of integrated samples over periods from 1 h to 24 h, or longer. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/D7459-25
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian