Show simple item record

Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout

contributor authorACI - American Concrete Institute
date accessioned2017-09-04T18:31:38Z
date available2017-09-04T18:31:38Z
date copyright06/01/2010
date issued2010
identifier otherIZNMTCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho162sAF679D40AC429654DD6EFDEC9FCD/handle/yse/213923
description abstractThis test method is designed to determine the resistance to bleeding of freshly-mixed cementitious grout under static pressure.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This test method does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user of this test method to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.*)
*Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, V. 04.02.
languageEnglish
titleACI 423.9Mnum
titleTest Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grouten
typestandard
page7
statusActive
treeACI - American Concrete Institute:;2010
contenttypefulltext
subject keywordsbleed stability
subject keywordsbleed water
subject keywordsbleeding
subject keywordsgrout
subject keywordsposttensioning
subject keywordspressure