ACI 423.9M
Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout
Organization:
ACI - American Concrete Institute
Year: 2010
Abstract: This test method is designed to determine the resistance to bleeding of freshly-mixed cementitious grout under static pressure.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This test method does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user of this test method to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.*)
*Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, V. 04.02.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This test method does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user of this test method to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.*)
*Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, V. 04.02.
Subject: bleed stability
Collections
:
Show full item record
contributor author | ACI - American Concrete Institute | |
date accessioned | 2017-09-04T18:31:38Z | |
date available | 2017-09-04T18:31:38Z | |
date copyright | 06/01/2010 | |
date issued | 2010 | |
identifier other | IZNMTCAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;query=autho162sAF679D40AC429654DD6EFDEC9FCD/handle/yse/213923 | |
description abstract | This test method is designed to determine the resistance to bleeding of freshly-mixed cementitious grout under static pressure. The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. This test method does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user of this test method to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.*) *Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, V. 04.02. | |
language | English | |
title | ACI 423.9M | num |
title | Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout | en |
type | standard | |
page | 7 | |
status | Active | |
tree | ACI - American Concrete Institute:;2010 | |
contenttype | fulltext | |
subject keywords | bleed stability | |
subject keywords | bleed water | |
subject keywords | bleeding | |
subject keywords | grout | |
subject keywords | posttensioning | |
subject keywords | pressure |