• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • UL - UL
  • View Item
  •   YSE
  • Industrial Standards
  • UL - UL
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

UL 162

UL Standard for Safety Foam Equipment and Liquid Concentrates - Seventh Edition; Reprint with revisions through and including September 8, 1999

Organization:
UL - UL
Year: 1994

Abstract: These requirements cover foam producing equipment and liquid concentrates employed for the production and discharge of foam that has an expansion ratio of 20:1 or less and is used for fire extinguishment. These requirements are based on the premise that foam equipment and specified types of foam liquid concentrates with which they are intended to be used are to be investigated for use with each other.
If foam equipment covered by these requirements incorporate sprinklers, the sprinklers shall comply with the Standard for Automatic Sprinklers for Fire Protection Service, UL 199.
Requirements for the installation and use of foam equipment and liquid concentrates are included in the following standards of the National Fire Protection Association:
a) Low Expansion Foam and Combined Agent Systems, NFPA 11;
b) Deluge Foam-Water Sprinkler and Spray Systems, NFPA 16;
c) Installation of Closed-Head Foam-Water Sprinkler Systems, NFPA 16A.
A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire, electric shock, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements to determine that the level of safety as originally anticipated by the intent of this standard is maintained. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard shall not be judged to comply with this standard. Where appropriate, revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
URI: http://yse.yabesh.ir/std;jsessioutho1513AF679D40527369728F1E273C014A/handle/yse/60859
Collections :
  • UL - UL
  • Download PDF : (3.163Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 162

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T15:57:34Z
date available2017-09-04T15:57:34Z
date copyright03/30/1994
date issued1994
identifier otherRASMJAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessioutho1513AF679D40527369728F1E273C014A/handle/yse/60859
description abstractThese requirements cover foam producing equipment and liquid concentrates employed for the production and discharge of foam that has an expansion ratio of 20:1 or less and is used for fire extinguishment. These requirements are based on the premise that foam equipment and specified types of foam liquid concentrates with which they are intended to be used are to be investigated for use with each other.
If foam equipment covered by these requirements incorporate sprinklers, the sprinklers shall comply with the Standard for Automatic Sprinklers for Fire Protection Service, UL 199.
Requirements for the installation and use of foam equipment and liquid concentrates are included in the following standards of the National Fire Protection Association:
a) Low Expansion Foam and Combined Agent Systems, NFPA 11;
b) Deluge Foam-Water Sprinkler and Spray Systems, NFPA 16;
c) Installation of Closed-Head Foam-Water Sprinkler Systems, NFPA 16A.
A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire, electric shock, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements to determine that the level of safety as originally anticipated by the intent of this standard is maintained. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard shall not be judged to comply with this standard. Where appropriate, revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
languageEnglish
titleUL 162num
titleUL Standard for Safety Foam Equipment and Liquid Concentrates - Seventh Edition; Reprint with revisions through and including September 8, 1999en
typestandard
page52
statusActive
treeUL - UL:;1994
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian