• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

ASHRAE LV-11-C034

Quantifying Chemical/Biological Event Severity with Vulnerability-Based Performance Metrics

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2011

Abstract: ABSTRACT
Quantifying the impact of chemical or biological releases on a building and its occupants is a necessary part of risk assessment. The most informative metrics for this purpose are absolute, "threat-based" measures of lost or preserved assets that are specific to the agent of interest. Practical application of threat-based metrics may be difficult because data such as the maximum plausible release quantity and dose response characteristics for an agent may be unavailable. In addition, it is left to the judgment of the analyst to select appropriate agents on which to base risk management decisions. Relative metrics are an alternative to absolute metrics that compare quantities such as exposure without respect to the specific agent. Such metrics may be described as "vulnerability-based" because their values reflect the influence of the building and its systems on exposure, independent of the agent. Vulnerability-based metrics are generally easier to determine but harder to interpret than threat-based metrics. The ordered, area-weighted distribution of concentration raised to a power corresponding to the toxic load exponent of an agent was selected for investigation as the basis of a vulnerability-based metric. Metric values were computed from concentration time histories generated by multizone model simulations of indoor agent releases. It was found that metrics derived from this distribution can distinguish between the severity and extent of different releases. Although easier to apply to the results of multizone modeling, the proposed metric can, in principle, also be applied to experimental data.
URI: http://yse.yabesh.ir/std;query=autho162sear79D/handle/yse/231547
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (1.221Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE LV-11-C034

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:50:11Z
date available2017-09-04T18:50:11Z
date copyright01/01/2011
date issued2011
identifier otherKTXTKEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho162sear79D/handle/yse/231547
description abstractABSTRACT
Quantifying the impact of chemical or biological releases on a building and its occupants is a necessary part of risk assessment. The most informative metrics for this purpose are absolute, "threat-based" measures of lost or preserved assets that are specific to the agent of interest. Practical application of threat-based metrics may be difficult because data such as the maximum plausible release quantity and dose response characteristics for an agent may be unavailable. In addition, it is left to the judgment of the analyst to select appropriate agents on which to base risk management decisions. Relative metrics are an alternative to absolute metrics that compare quantities such as exposure without respect to the specific agent. Such metrics may be described as "vulnerability-based" because their values reflect the influence of the building and its systems on exposure, independent of the agent. Vulnerability-based metrics are generally easier to determine but harder to interpret than threat-based metrics. The ordered, area-weighted distribution of concentration raised to a power corresponding to the toxic load exponent of an agent was selected for investigation as the basis of a vulnerability-based metric. Metric values were computed from concentration time histories generated by multizone model simulations of indoor agent releases. It was found that metrics derived from this distribution can distinguish between the severity and extent of different releases. Although easier to apply to the results of multizone modeling, the proposed metric can, in principle, also be applied to experimental data.
languageEnglish
titleASHRAE LV-11-C034num
titleQuantifying Chemical/Biological Event Severity with Vulnerability-Based Performance Metricsen
typestandard
page8
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian