ASHRAE ST-16-001
English -- Analyzing the Performance of a Kitchen Exhaust Air Duct with Regards to Recent Standards-A CFD/Thermal-Stress Simulation
Year: 2016
Abstract: Scope: Recent standards have defined a lower minimum air velocity in kitchen exhaust air ducts without compromising performance. Steel ducts are usually specified to a standard steel gage thickness capable of handling the extreme load conditions of high temperatures, possible corrosive conditions, and negative pressure levels within exhaust duct. This paper simulates a typical kitchen exhaust air duct performing under extreme temperature conditions and low air duct velocities. Lower exhaust air velocities should correspond to lower in-duct negative pressure values and, therefore, possibly a reduction in steel duct wall thickness. A computational fluid dynamics (CFD)/thermal stress analysis was carried out under the most extreme load conditions specified under recently issued standards. This analysis demonstrates that a lower-gage steel duct thickness is more than sufficient than what is specified in recent standards, and, therefore, a lower-gage steel thickness can be used.
-
Statistics
ASHRAE ST-16-001
Show full item record
| contributor author | ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. | |
| date accessioned | 2017-10-18T10:58:49Z | |
| date available | 2017-10-18T10:58:49Z | |
| date copyright | 2016.01.01 | |
| date issued | 2016 | |
| identifier other | KHBQSFAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;query=autho162sear79D/handle/yse/233229 | |
| description abstract | Scope: Recent standards have defined a lower minimum air velocity in kitchen exhaust air ducts without compromising performance. Steel ducts are usually specified to a standard steel gage thickness capable of handling the extreme load conditions of high temperatures, possible corrosive conditions, and negative pressure levels within exhaust duct. This paper simulates a typical kitchen exhaust air duct performing under extreme temperature conditions and low air duct velocities. Lower exhaust air velocities should correspond to lower in-duct negative pressure values and, therefore, possibly a reduction in steel duct wall thickness. A computational fluid dynamics (CFD)/thermal stress analysis was carried out under the most extreme load conditions specified under recently issued standards. This analysis demonstrates that a lower-gage steel duct thickness is more than sufficient than what is specified in recent standards, and, therefore, a lower-gage steel thickness can be used. | |
| language | English | |
| title | ASHRAE ST-16-001 | num |
| title | English -- Analyzing the Performance of a Kitchen Exhaust Air Duct with Regards to Recent Standards-A CFD/Thermal-Stress Simulation | en |
| type | standard | |
| page | 7 | |
| status | Active | |
| tree | ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016 | |
| contenttype | fulltext |

درباره ما