IPC TM-650 2.6.15C
Corrosion, Flux
Organization:
IPC - Association Connecting Electronics Industries
Year: 2004
Abstract: This test method is designed to determine the corrosive properties of flux residues under extreme environmental conditions. A pellet of solder is melted in contact with the test flux on a sheet metal test piece. The solder is then exposed to prescribed conditions of humidity and the resulting corrosion, if any, is assessed visually.
Collections
:
-
Statistics
IPC TM-650 2.6.15C
Show full item record
| contributor author | IPC - Association Connecting Electronics Industries | |
| date accessioned | 2017-09-04T16:49:35Z | |
| date available | 2017-09-04T16:49:35Z | |
| date copyright | 06/01/2004 | |
| date issued | 2004 | |
| identifier other | WLLGIBAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;query=autho18267D83FCDCAC6/handle/yse/113095 | |
| description abstract | This test method is designed to determine the corrosive properties of flux residues under extreme environmental conditions. A pellet of solder is melted in contact with the test flux on a sheet metal test piece. The solder is then exposed to prescribed conditions of humidity and the resulting corrosion, if any, is assessed visually. | |
| language | English | |
| title | IPC TM-650 2.6.15C | num |
| title | Corrosion, Flux | en |
| type | standard | |
| page | 3 | |
| status | Active | |
| tree | IPC - Association Connecting Electronics Industries:;2004 | |
| contenttype | fulltext |