ASME PTC 46

Performance Test Code on Overall Plant Performance

Organization:
ASME - ASME International
Year: 1996

Abstract: OBJECT AND SCOPE
This Code applies to any plant size. It can be used to measure the performance of a plant in its normal operating condition, with all equipment in a clean and fully-functional condition. This Code provides explicit methods and procedures for combined-cycle power plants and for most gas, liquid, and solid fueled Rankine cycle plants. There is no intent to restrict the use of this Code for other types of heat-cycle power plants, providing the explicit procedures can be met. It does not, however, apply to simple-cycle gas turbine power plants (see ASME PTC 22 instead). The scope of this Code begins for a gas turbine-based power generating unit when a heat-recovery steam generator is included within the test boundary.
To test a particular power plant or cogeneration facility, the following conditions must be met.
(a) a means must be available to determine, through either direct or indirect measurements, all of the heat inputs entering the test boundary and all of the electrical power and secondary outputs leaving the test boundary;
(b) a means must be available to determine, through either direct or indirect measurements, all of the parameters to correct the results from the test to the base reference condition;
(c) the test result uncertainties are expected to be less than or equal to the uncertainties given in Subsection 1.3 for the applicable plant type; and
(d) the working fluid for vapor cycles must be steam. This restriction is imposed only to the extent that other fluids may require measurements or measurement methods different from those provided by this Code for steam cycles. In addition, this Code does not provide specific references for the properties of working fluids other than steam.
Tests addressing other power plant performance-related issues are outside the scope of this Code. These include the following:
emissions tests: testing to verify compliance with regulatory emissions levels (e.g., airborne gaseous and particulate, solid and wastewater, noise, etc.), or required for calibration and certification of emission-monitoring systems.
operational demonstration tests: the various standard power plant tests typically conducted during start-up, or periodically thereafter, to demonstrate specified operating capabilities (e.g., minimum load operation, automatic load control and load ramp rate, fuel switching capability, etc.).
reliability tests: tests conducted over an extended period of days or weeks to demonstrate the capability of the power plant to produce a specified minimum output level or availability. The measurement methods, calculations, and corrections to design conditions included herein may be of use in designing tests of this type; however, this Code does not address this type of testing in terms of providing explicit testing procedures or acceptance criteria.
URI: http://yse.yabesh.ir/std;query=autho1826AF679D4049A961598F1EFDEC014A0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/224683
Collections :
  • ASME - ASME International
  • Download PDF : (9.609Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASME PTC 46

Show full item record

contributor authorASME - ASME International
date accessioned2017-09-04T18:43:15Z
date available2017-09-04T18:43:15Z
date copyright1996.01.01
date issued1996
identifier otherKBNADAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho1826AF679D4049A961598F1EFDEC014A0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/224683
description abstractOBJECT AND SCOPE
This Code applies to any plant size. It can be used to measure the performance of a plant in its normal operating condition, with all equipment in a clean and fully-functional condition. This Code provides explicit methods and procedures for combined-cycle power plants and for most gas, liquid, and solid fueled Rankine cycle plants. There is no intent to restrict the use of this Code for other types of heat-cycle power plants, providing the explicit procedures can be met. It does not, however, apply to simple-cycle gas turbine power plants (see ASME PTC 22 instead). The scope of this Code begins for a gas turbine-based power generating unit when a heat-recovery steam generator is included within the test boundary.
To test a particular power plant or cogeneration facility, the following conditions must be met.
(a) a means must be available to determine, through either direct or indirect measurements, all of the heat inputs entering the test boundary and all of the electrical power and secondary outputs leaving the test boundary;
(b) a means must be available to determine, through either direct or indirect measurements, all of the parameters to correct the results from the test to the base reference condition;
(c) the test result uncertainties are expected to be less than or equal to the uncertainties given in Subsection 1.3 for the applicable plant type; and
(d) the working fluid for vapor cycles must be steam. This restriction is imposed only to the extent that other fluids may require measurements or measurement methods different from those provided by this Code for steam cycles. In addition, this Code does not provide specific references for the properties of working fluids other than steam.
Tests addressing other power plant performance-related issues are outside the scope of this Code. These include the following:
emissions tests: testing to verify compliance with regulatory emissions levels (e.g., airborne gaseous and particulate, solid and wastewater, noise, etc.), or required for calibration and certification of emission-monitoring systems.
operational demonstration tests: the various standard power plant tests typically conducted during start-up, or periodically thereafter, to demonstrate specified operating capabilities (e.g., minimum load operation, automatic load control and load ramp rate, fuel switching capability, etc.).
reliability tests: tests conducted over an extended period of days or weeks to demonstrate the capability of the power plant to produce a specified minimum output level or availability. The measurement methods, calculations, and corrections to design conditions included herein may be of use in designing tests of this type; however, this Code does not address this type of testing in terms of providing explicit testing procedures or acceptance criteria.
languageEnglish
titleASME PTC 46num
titlePerformance Test Code on Overall Plant Performanceen
typestandard
page192
statusActive
treeASME - ASME International:;1996
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian