DIN EN 12200-1

English -- Plastics rainwater piping systems for above ground external use - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system;
German -- Kunststoff-Rohrleitungssysteme fuer aussenliegende Regenfallleitungen - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an Rohre, Formstuecke und das Rohrleitungssystem

Organization:
DIN - Deutsches Institut fš?r Normung e. V.
Year: 2016

Abstract: Scope: This European Standard specifies the requirements for pipes, fittings, brackets and the system of unplasticized poly(vinyl chloride) (PVC-U) intended for use as above-ground external rainwater piping systems. It also specifies: a) The requirements for metallic brackets. b) Both solid wall pipes and fittings, (i.e. product manufactured from a single layer), as well as solid wall multi-layer pipes. c) The test parameters for the test methods referred to in this standard. Pipes can be used in conjunction with fittings and brackets of acrylic materials provided these polymers meet the performance requirements of this standard. The products are usually used in conjunction with gutters conforming to EN 607 [1]. They are not intended for use with products conforming to EN 612 [2]. This standard is applicable to PVC-U rainwater systems of circular, square, rectangular or any other shape with sealed (rubber ring or solvent cement) or unsealed joints. This standard covers a range of pipes and fittings sizes. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from the size range to take into account their particular requirements and any relevant national regulations and installation practices or codes. NOTE 2 The term “rainwater” in this standard is used also to encompass “surface water” (as defined in EN 752 [6]) run-off from buildings.
URI: http://yse.yabesh.ir/std;query=autho1826AF679D4052736159DD6E273C9FCD/handle/yse/236418
Collections :
  • DIN - Deutsches Institut für Normung e. V.
  • Download PDF : (2.006Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    DIN EN 12200-1

Show full item record

contributor authorDIN - Deutsches Institut fš?r Normung e. V.
date accessioned2017-10-18T11:12:19Z
date available2017-10-18T11:12:19Z
date copyright2016.10.01
date issued2016
identifier otherCRJGSFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho1826AF679D4052736159DD6E273C9FCD/handle/yse/236418
description abstractScope: This European Standard specifies the requirements for pipes, fittings, brackets and the system of unplasticized poly(vinyl chloride) (PVC-U) intended for use as above-ground external rainwater piping systems. It also specifies: a) The requirements for metallic brackets. b) Both solid wall pipes and fittings, (i.e. product manufactured from a single layer), as well as solid wall multi-layer pipes. c) The test parameters for the test methods referred to in this standard. Pipes can be used in conjunction with fittings and brackets of acrylic materials provided these polymers meet the performance requirements of this standard. The products are usually used in conjunction with gutters conforming to EN 607 [1]. They are not intended for use with products conforming to EN 612 [2]. This standard is applicable to PVC-U rainwater systems of circular, square, rectangular or any other shape with sealed (rubber ring or solvent cement) or unsealed joints. This standard covers a range of pipes and fittings sizes. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from the size range to take into account their particular requirements and any relevant national regulations and installation practices or codes. NOTE 2 The term “rainwater” in this standard is used also to encompass “surface water” (as defined in EN 752 [6]) run-off from buildings.
languageEnglish
titleDIN EN 12200-1num
titleEnglish -- Plastics rainwater piping systems for above ground external use - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the systemen
titleGerman -- Kunststoff-Rohrleitungssysteme fuer aussenliegende Regenfallleitungen - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an Rohre, Formstuecke und das Rohrleitungssystemother
typestandard
page36
statusActive
treeDIN - Deutsches Institut fš?r Normung e. V.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian