Archive

English -- Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile or Expanded Vinyl Wall Coverings on Full Height Panels and Walls - Effective Date: 11/25/2018

NFPA 265

Organization:
NFPA - (NFPA) - National Fluid Power Association
Year: 2019

Abstract: Scope: This standard describes a test method for determining the contribution of textile or expanded vinyl wall coverings to room fire growth during specified fire exposure conditions. This test method shall be used to evaluate the flammability characteristics of textile or expanded vinyl wall coverings where such materials constitute the exposed interior surfaces of buildings and demountable, relocatable, full height partitions used in open building interiors. This test method shall not be used to evaluate the fire resistance of assemblies, nor shall it be used to evaluate the effect of fires originating within a wall assembly. This test method shall not be used for the evaluation of floor or ceiling finishes. This test method shall not apply to fabric-covered, lower-than-ceiling-height, freestanding, prefabricated panel furniture systems. Purpose.  This test method shall measure certain fire performance characteristics of textile or expanded vinyl wall covering materials in an enclosure under specified fire exposure conditions. This test method shall determine the potential extent to which the textile or expanded vinyl wall covering materials contribute to fire growth in a room and the potential for fire spread beyond the room under the particular conditions simulated.
URI: http://yse.yabesh.ir/std;query=autho1826AF67FCDC527361598F1EFDEC014A/handle/yse/281258
Collections :
  • NFPA - (NFPA) - National Fluid Power Association
  • Download PDF : (592.4Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    English -- Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile or Expanded Vinyl Wall Coverings on Full Height Panels and Walls - Effective Date: 11/25/2018

Show full item record

contributor authorNFPA - (NFPA) - National Fluid Power Association
date accessioned2020-08-15T17:29:36Z
date available2020-08-15T17:29:36Z
date copyright2019.01.01
date issued2019
identifier otherZUDQGGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho1826AF67FCDC527361598F1EFDEC014A/handle/yse/281258
description abstractScope: This standard describes a test method for determining the contribution of textile or expanded vinyl wall coverings to room fire growth during specified fire exposure conditions. This test method shall be used to evaluate the flammability characteristics of textile or expanded vinyl wall coverings where such materials constitute the exposed interior surfaces of buildings and demountable, relocatable, full height partitions used in open building interiors. This test method shall not be used to evaluate the fire resistance of assemblies, nor shall it be used to evaluate the effect of fires originating within a wall assembly. This test method shall not be used for the evaluation of floor or ceiling finishes. This test method shall not apply to fabric-covered, lower-than-ceiling-height, freestanding, prefabricated panel furniture systems. Purpose.  This test method shall measure certain fire performance characteristics of textile or expanded vinyl wall covering materials in an enclosure under specified fire exposure conditions. This test method shall determine the potential extent to which the textile or expanded vinyl wall covering materials contribute to fire growth in a room and the potential for fire spread beyond the room under the particular conditions simulated.
languageEnglish
titleEnglish -- Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile or Expanded Vinyl Wall Coverings on Full Height Panels and Walls - Effective Date: 11/25/2018en
titleNFPA 265num
typestandard
page31
statusActive
treeNFPA - (NFPA) - National Fluid Power Association:;2019
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش