ECA EIA-364-19A
TP-19A Torsional Insert Retention Test Procedure for Electrical Connectors
Organization:
ECIA - Electronic Components Industry Association
Year: 2008
Abstract: This standard establishes test methods to determine the ability of the insert retaining system to withstand the torsional stresses likely to be encountered during normal usage.
Typical damage resulting £rom this test might be:
Cracked or broken inserts.
Inserts permanently displaced within connector shells.
Typical damage resulting £rom this test might be:
Cracked or broken inserts.
Inserts permanently displaced within connector shells.
Collections
:
-
Statistics
ECA EIA-364-19A
Show full item record
| contributor author | ECIA - Electronic Components Industry Association | |
| date accessioned | 2017-09-04T17:36:09Z | |
| date available | 2017-09-04T17:36:09Z | |
| date copyright | 04/01/2001 (R 2008) | |
| date issued | 2008 | |
| identifier other | DJXLGCAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;query=autho462sear3FCDCAC4/handle/yse/159059 | |
| description abstract | This standard establishes test methods to determine the ability of the insert retaining system to withstand the torsional stresses likely to be encountered during normal usage. Typical damage resulting £rom this test might be: Cracked or broken inserts. Inserts permanently displaced within connector shells. | |
| language | English | |
| title | ECA EIA-364-19A | num |
| title | TP-19A Torsional Insert Retention Test Procedure for Electrical Connectors | en |
| type | standard | |
| page | 12 | |
| status | Active | |
| tree | ECIA - Electronic Components Industry Association:;2008 | |
| contenttype | fulltext |

درباره ما