IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V - Corrigendum 1
IEEE Std C37.04-2018/Cor1-2021 (Corrigendum to IEEE Std C37.04-2018)
Year: 2021
Abstract: This standard covers the rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types. Preferred ratings are also provided. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A, 1200 A, 2000 A, 3000 A, and 4000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, insulation capability (formerly dielectric withstand voltages), short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. This standard does not cover generator circuit breakers, which are covered by IEC/IEEE Std 62271-37-013(TM).
Subject: interrupting time
-
Statistics
IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V - Corrigendum 1
Show full item record
contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
date accessioned | 2022-07-04T20:40:44Z | |
date available | 2022-07-04T20:40:44Z | |
date copyright | 24 Sept. 2021 | |
date issued | 2021 | |
identifier other | 9547240.pdf | |
identifier uri | http://yse.yabesh.ir/std;query=autho47037D83FCDCAC4261598F1EFDEC014A/handle/yse/312776 | |
description abstract | This standard covers the rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types. Preferred ratings are also provided. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A, 1200 A, 2000 A, 3000 A, and 4000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, insulation capability (formerly dielectric withstand voltages), short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. This standard does not cover generator circuit breakers, which are covered by IEC/IEEE Std 62271-37-013(TM). | |
language | English | |
title | IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V - Corrigendum 1 | en |
title | IEEE Std C37.04-2018/Cor1-2021 (Corrigendum to IEEE Std C37.04-2018) | num |
type | Standard | |
page | 17 | |
tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2021 | |
contenttype | Fulltext | |
subject keywords | interrupting time | |
subject keywords | power frequency | |
subject keywords | short-circuit current | |
subject keywords | indoor | |
subject keywords | short-line fault | |
subject keywords | mechanical endurance | |
subject keywords | insulation capability | |
subject keywords | outdoor | |
subject keywords | operating duty | |
subject keywords | capacitive current switching | |
subject keywords | related capabilities | |
subject keywords | ratings | |
subject keywords | transient recovery voltage | |
subject keywords | IEEE C37.04 | |
identifier DOI | 10.1109/IEEESTD.2021.9547240 |