TAPPI T 541 OM

Internal bond strength of paperboard (z-direction tensile)

Organization:
TAPPI - TAPPI
Year: 2010

Abstract: Scope and summary
This method describes a procedure for measuring the internal fiber bond strength (z-direction tensile strength) of paperboard using an instrument that subjects a normal separation force to a 6.45-cm2 (1-in.2) specimen.
The procedure consists of applying double (two-sided) coated, pressure-sensitive tape to both sides of a test specimen. The specimen is then placed between two platens and compressed uniformly over the entire specimen surface area. Uniform tension is then applied over the entire test area in a direction perpendicular to the plane of the sample (z-direction) to affect a separation.
The test is intended for paperboards and some papers which have internal fiber bond strength (cohesive strength) lower than the adhesive bond strength of the tape to the specimen and/or test platens. The material from which the platens are made will affect the adhesive strength between platen and tape. The selection of tape may also affect test results. These effects may be seen as tape failures or in some cases higher test values caused by adhesive migrating into sample. The adhesive bond strength of the tape is critical to reproducible test results. New batches of tape should be tested for consistent bond strength. Bond strength can be tested by performing peel tests on standard test plates, or by testing a stable reference sample.
Test results by this method do not correlate with TAPPI T 569 "Internal bond strength (Scott type)" measurements. TAPPI T 569 uses a pendulum that impacts the top inside surface of a platen at a high speed causing it to rotate and split the paper specimen.
URI: http://yse.yabesh.ir/std;query=autho47037D83FCDCAC426159DD6E273C9FCD/handle/yse/171921
Subject: Adhesion
Collections :
  • TAPPI - TAPPI
  • Download PDF : (48.75Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    TAPPI T 541 OM

Show full item record

contributor authorTAPPI - TAPPI
date accessioned2017-09-04T17:48:47Z
date available2017-09-04T17:48:47Z
date copyright2010.01.01
date issued2010
identifier otherERXEBDAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho47037D83FCDCAC426159DD6E273C9FCD/handle/yse/171921
description abstractScope and summary
This method describes a procedure for measuring the internal fiber bond strength (z-direction tensile strength) of paperboard using an instrument that subjects a normal separation force to a 6.45-cm2 (1-in.2) specimen.
The procedure consists of applying double (two-sided) coated, pressure-sensitive tape to both sides of a test specimen. The specimen is then placed between two platens and compressed uniformly over the entire specimen surface area. Uniform tension is then applied over the entire test area in a direction perpendicular to the plane of the sample (z-direction) to affect a separation.
The test is intended for paperboards and some papers which have internal fiber bond strength (cohesive strength) lower than the adhesive bond strength of the tape to the specimen and/or test platens. The material from which the platens are made will affect the adhesive strength between platen and tape. The selection of tape may also affect test results. These effects may be seen as tape failures or in some cases higher test values caused by adhesive migrating into sample. The adhesive bond strength of the tape is critical to reproducible test results. New batches of tape should be tested for consistent bond strength. Bond strength can be tested by performing peel tests on standard test plates, or by testing a stable reference sample.
Test results by this method do not correlate with TAPPI T 569 "Internal bond strength (Scott type)" measurements. TAPPI T 569 uses a pendulum that impacts the top inside surface of a platen at a high speed causing it to rotate and split the paper specimen.
languageEnglish
titleTAPPI T 541 OMnum
titleInternal bond strength of paperboard (z-direction tensile)en
typestandard
page4
statusActive
treeTAPPI - TAPPI:;2010
contenttypefulltext
subject keywordsAdhesion
subject keywordsBond strength
subject keywordsCohesion
subject keywordsFiber bonding
subject keywordsPaperboard
subject keywordsTensile strength
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian