AHRI 430

Performance Rating of Central Station Air-Handling Units

Organization:
AHRI - Air-Conditioning, Heating and Refrigeration Institute
Year: 2009

Abstract: This standard applies to central station air-handling units, as defined in Section 3.
This standard applies to supply fan ratings for double width double inlet (DWDI) housed fans, axial fans, and full opening axial discharge plenum fans in a cabinet.
Exclusions.
This standard does not apply to forced-circulation, free-delivery air-coolers for refrigeration, which are covered in AHRI Standard 420.
This standard does not apply to unit heaters intended for free delivery of heated air or to room fan-coils as defined in AHRI Standard 440.
This standard does not apply to units that have direct expansion coils incorporated by the manufacturer in a matched split system air-conditioner, or as otherwise defined in the product scope definition of the AHRI Unitary Small Equipment and Unitary Large Equipment Sections and covered in AHRI Standard 210/240 or in AHRI Standard 340/360.
This standard does not apply to unit ventilators as defined in AHRI Standard 840.
Purpose. The purpose of this standard is to establish for Central Station Air-Handling Units: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions.
Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, and users.
Review and Amendment. This standard is subject to review and amendment as technology advances.
URI: http://yse.yabesh.ir/std;query=autho47037D83FCDCAC426159DD6EFDEC014A/handle/yse/185444
Collections :
  • AHRI - Air-Conditioning, Heating and Refrigeration Institute
  • Download PDF : (1.162Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    AHRI 430

Show full item record

contributor authorAHRI - Air-Conditioning, Heating and Refrigeration Institute
date accessioned2017-09-04T18:02:25Z
date available2017-09-04T18:02:25Z
date copyright01/01/2009
date issued2009
identifier otherGBWFRCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho47037D83FCDCAC426159DD6EFDEC014A/handle/yse/185444
description abstractThis standard applies to central station air-handling units, as defined in Section 3.
This standard applies to supply fan ratings for double width double inlet (DWDI) housed fans, axial fans, and full opening axial discharge plenum fans in a cabinet.
Exclusions.
This standard does not apply to forced-circulation, free-delivery air-coolers for refrigeration, which are covered in AHRI Standard 420.
This standard does not apply to unit heaters intended for free delivery of heated air or to room fan-coils as defined in AHRI Standard 440.
This standard does not apply to units that have direct expansion coils incorporated by the manufacturer in a matched split system air-conditioner, or as otherwise defined in the product scope definition of the AHRI Unitary Small Equipment and Unitary Large Equipment Sections and covered in AHRI Standard 210/240 or in AHRI Standard 340/360.
This standard does not apply to unit ventilators as defined in AHRI Standard 840.
Purpose. The purpose of this standard is to establish for Central Station Air-Handling Units: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions.
Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, and users.
Review and Amendment. This standard is subject to review and amendment as technology advances.
languageEnglish
titleAHRI 430num
titlePerformance Rating of Central Station Air-Handling Unitsen
typestandard
page21
statusActive
treeAHRI - Air-Conditioning, Heating and Refrigeration Institute:;2009
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian