• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • IEC - International Electrotechnical Commission
  • View Item
  •   YSE
  • Industrial Standards
  • IEC - International Electrotechnical Commission
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

French -- Appareillage à haute tension – Partie 107: Circuits-switchers fusiblés pour courant alternatif de tension assignée supérieure à 1 kV et jusqu'à 52 kV inclus - Edition 3.0|English -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0

IEC 62271-107

Organization:
IEC - International Electrotechnical Commission
Year: 2019

Abstract: Scope: This part of IEC 62271 applies to three-pole-operated fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. They can be designed either as stand-alone devices, or be embedded in a switchgear and controlgear assembly. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Current-limiting fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher alone. NOTE 1 In this document, the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. NOTE 2 Other circuit-switchers exist; see reference [4]. Devices that require a dependent manual operation are not covered by this document.
URI: http://yse.yabesh.ir/std;query=autho47037D83FCDCAC426159DD6EFDEC9FCD/handle/yse/289011
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (2.100Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    French -- Appareillage à haute tension – Partie 107: Circuits-switchers fusiblés pour courant alternatif de tension assignée supérieure à 1 kV et jusqu'à 52 kV inclus - Edition 3.0|English -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:28:21Z
date available2020-09-15T22:28:21Z
date copyright2019.05.01
date issued2019
identifier otherSOOYHGAAAAAAAAAA.pdf
identifier otherSOOYHGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho47037D83FCDCAC426159DD6EFDEC9FCD/handle/yse/289011
description abstractScope: This part of IEC 62271 applies to three-pole-operated fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. They can be designed either as stand-alone devices, or be embedded in a switchgear and controlgear assembly. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Current-limiting fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher alone. NOTE 1 In this document, the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. NOTE 2 Other circuit-switchers exist; see reference [4]. Devices that require a dependent manual operation are not covered by this document.
languageEnglish, French
titleFrench -- Appareillage à haute tension – Partie 107: Circuits-switchers fusiblés pour courant alternatif de tension assignée supérieure à 1 kV et jusqu'à 52 kV inclus - Edition 3.0|English -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0en
titleIEC 62271-107num
typestandard
page114
statusActive
treeIEC - International Electrotechnical Commission:;2019
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش