Show simple item record

TP-53B Nitric Acid Vapor Test, Gold Finish Test Procedure for Electrical Connectors and Sockets

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T17:11:12Z
date available2017-09-04T17:11:12Z
date copyright05/01/2000 (R 2007)
date issued2007
identifier otherYRWVYBAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho470393FD081D20686159DD6EFDEC9FCD0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/134747
description abstractThis standard establishes test methods to determine the magnitude of porosity as well as other surface defects inherent in application of gold contact finishes.
Object
It is the intent that the defined method be used as an evaluation technique for the acceptability of gold contact finishes. The method described herein has been selected on the basis of simplicity of equipment, setup and operation. This procedure applies only to gold finishes with or without underplates applied to copper or nickel base alloy contacts. This test procedure does not apply to gold flash, equal to less than 0.25 micrometer (10 microinches), over palladium or palladium alloy systems, see EIA-364-60.
languageEnglish
titleECA EIA/ECA-364-53Bnum
titleTP-53B Nitric Acid Vapor Test, Gold Finish Test Procedure for Electrical Connectors and Socketsen
typestandard
page24
statusActive
treeECIA - Electronic Components Industry Association:;2007
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record