ECA EIA/ECA-364-53B

TP-53B Nitric Acid Vapor Test, Gold Finish Test Procedure for Electrical Connectors and Sockets

Organization:
ECIA - Electronic Components Industry Association
Year: 2007

Abstract: This standard establishes test methods to determine the magnitude of porosity as well as other surface defects inherent in application of gold contact finishes.
Object
It is the intent that the defined method be used as an evaluation technique for the acceptability of gold contact finishes. The method described herein has been selected on the basis of simplicity of equipment, setup and operation. This procedure applies only to gold finishes with or without underplates applied to copper or nickel base alloy contacts. This test procedure does not apply to gold flash, equal to less than 0.25 micrometer (10 microinches), over palladium or palladium alloy systems, see EIA-364-60.
URI: http://yse.yabesh.ir/std;query=autho470393FD081D20686159DD6EFDEC9FCD0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/134747
Collections :
  • ECIA - Electronic Components Industry Association
  • Download PDF : (166.5Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ECA EIA/ECA-364-53B

Show full item record

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T17:11:12Z
date available2017-09-04T17:11:12Z
date copyright05/01/2000 (R 2007)
date issued2007
identifier otherYRWVYBAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho470393FD081D20686159DD6EFDEC9FCD0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/134747
description abstractThis standard establishes test methods to determine the magnitude of porosity as well as other surface defects inherent in application of gold contact finishes.
Object
It is the intent that the defined method be used as an evaluation technique for the acceptability of gold contact finishes. The method described herein has been selected on the basis of simplicity of equipment, setup and operation. This procedure applies only to gold finishes with or without underplates applied to copper or nickel base alloy contacts. This test procedure does not apply to gold flash, equal to less than 0.25 micrometer (10 microinches), over palladium or palladium alloy systems, see EIA-364-60.
languageEnglish
titleECA EIA/ECA-364-53Bnum
titleTP-53B Nitric Acid Vapor Test, Gold Finish Test Procedure for Electrical Connectors and Socketsen
typestandard
page24
statusActive
treeECIA - Electronic Components Industry Association:;2007
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian